MétaCan
Menu
Back to cohort
Record W4224307707 · doi:10.1002/mp.15671

Technical note: Characterization and practical applications of a novel plastic scintillator for online dosimetry for an ultrahigh dose rate (FLASH)

2022· article· en· W4224307707 on OpenAlexaff
Yannick Poirier, Junliang Xu, Sina Mossahebi, François Therriault‐Proulx, Amit Sawant

Bibliographic record

VenueMedical Physics · 2022
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsRio Tinto (Canada)McGill University
Fundersnot available
KeywordsScintillatorDosimetryDosimeterIonization chamberFlash (photography)Materials scienceDose profileLinear particle acceleratorCalibrationNuclear medicineOpticsMedical physicsPhysicsIonizationDetectorMedicineIon

Abstract

fetched live from OpenAlex

PURPOSE: Although flash radiation therapy (FLASH-RT) is a promising novel technique that has the potential to achieve a better therapeutic ratio between tumor control and normal tissue complications, the ultrahigh pulsed dose rates (UHPDR) mean that experimental dosimetry is very challenging. There is a need for real-time dosimeters in the development and implementation of FLASH-RT. In this work, we characterize a novel plastic scintillator capable of temporal resolution short enough (2.5 ms) to resolve individual pulses. METHODS: We characterized a novel plastic dosimeter for use in a linac converter to deliver 16-MeV electrons at 100-Gy/s UHPDR average dose rates. The linearity and reproducibility were established by comparing relative measurements with a pinpoint ionization chamber placed at 10-cm water-equivalent depth where the electrometer is not saturated by the high dose per pulse. The accuracy was established by comparing the plastic scintillator dose measurements with EBT-XD Gafchromic radiochromic films, the current reference dosimeter for UHPDR. Finally, the plastic scintillator was compared against EBT-XD films for online dosimetry of two in vitro experiments performed at UHPDR. RESULTS: Relative ion chamber measurements were linear with plastic scintillator response within ≤1% over 4-20 Gy and pulse frequencies (18-180 Hz). When characterized under reference conditions with NIST-traceability, the plastic scintillator maintained its dose response under UHPDR conditions and agreed with EBT-XD film dose measurements within 4% under reference conditions and 6% for experimental online dosimetry. CONCLUSION: The plastic scintillator shows a linear and reproducible response and is able to accurately measure the radiation absorbed dose delivered by 16-MeV electrons at UHPDR. The dose is measured accurately in real time with a greater level of precision than that achieved with a radiochromic film.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.866
Threshold uncertainty score0.538

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.339
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations50
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207