PERENCANAAN SISTEM PLAMBING AIR BERSIH DAN AIR LIMBAH DI RUMAH SAKIT X BANDUNG

2022· article· id· W4224879191 on OpenAlexaff
Fillya Vallyana Novarizal, Kancitra Pharmawati, Anindito Nurprabowo

Bibliographic record

VenueJukung (Jurnal Teknik Lingkungan) · 2022
Typearticle
Languageid
FieldComputer Science
TopicEnvironmental Engineering and Cultural Studies
Canadian institutionsEncana (Canada)
Fundersnot available
KeywordsEnvironmental scienceWaste managementEnvironmental engineeringForestryPhysicsGeographyEngineering

Abstract

fetched live from OpenAlex

Rumah Sakit X dibangun untuk memenuhi kebutuhan fasilitas rumah sakit di Kota Bandung. Salah satu sarana penunjang untuk meningkatkan pelayanan kesehatan rumah sakit adalah prasarana sanitasi mencakup sistem plambing. Perencanaan sistem plambing sangat dibutuhkan untuk menunjang penyediaan air bersih dan penyaluran air limbah. Penyediaan kebutuhan air bersih dapat ditentukan berdasarkan jumlah populasi. Sistem pengaliran yang dugunakan adalah sistem tangki atap, dimana air akan ditampung terlebih dahulu pada tangki bawah kemudian dipompa menuju tangki atap lalu dialirkan secara gravitasi ke setiap alat plambing. Penyaluran air limbah menggunakan sistem gravitasi, dimana air limbah yang dihasilkan dari setiap alat plambing dialirkan ke Instalasi Pengolahan Air Limbah (IPAL) dan Sewage Treatment Plant (STP). Perencanaan jalur dan dimensi pipa mengacu pada SNI 8153-2015. Jenis pipa yang digunakan untuk air bersih adalah Poly Propilene Random (PPR) dan untuk air limbah adalah PolyVinyl Chloride (PVC) dengan diameter berada pada rentang 20 mm sampai 114 mm. Kata kunci : Air Bersih, Air Limbah, Sistem Plambing. Hospital X was built to meet the needs of hospital facilities in the city of Bandung. One of the supporting facilities to improve hospital health services is sanitation infrastructure including a plumbing system. Plumbing system planning is needed to support the provision of clean water and waste water distribution. Provision of clean water needs can be determined based on the number of population. The drainage system used is the roof tank system, where the water will be accommodated first in the lower tank and then pumped to the roof tank and then flowed by gravity to each plumbing device. The distribution of waste water uses a gravity system, where waste water generated from each plumbing device is transferred to the Sewage Treatment Plant (STP) Wastewater Treatment Plant (IPAL). Line planning and pipe dimensions refer to SNI 8153-2015. The type of pipe used for clean water is Poly Propylene Random (PPR) and for waste water is PolyVinyl Chloride (PVC) with diameters ranging from 20 mm to 114 mm. Keywords: Clean Water, Plumbing System, Waste Water.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.034
Threshold uncertainty score0.113

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0020.001
Scholarly communication0.0030.001
Open science0.0010.002
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0340.010

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.202
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJukung (Jurnal Teknik Lingkungan)Same topicEnvironmental Engineering and Cultural StudiesFrench-language works237,207