MétaCan
Menu
Back to cohort
Record W4225263078 · doi:10.1097/cce.0000000000000689

Association of Respiratory Parameters at Venovenous Extracorporeal Membrane Oxygenation Liberation With Duration of Mechanical Ventilation and ICU Length of Stay: A Prospective Cohort Study

2022· article· en· W4225263078 on OpenAlexaff
Sonny Thiara, Ary Serpa Neto, Aidan Burrell, Bentley J. Fulcher, Carol Hodgson

Bibliographic record

VenueCritical Care Explorations · 2022
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMedicineExtracorporeal membrane oxygenationMechanical ventilationInterquartile rangeAnesthesiaVentilation (architecture)OxygenationRespiratory distressProspective cohort studySurgery

Abstract

fetched live from OpenAlex

OBJECTIVES: Although the criteria for initiation of venovenous extracorporeal membrane oxygenation (VV ECMO) are well defined, the criteria and timing for VV ECMO decannulation are less certain. The aim of this study was to describe the ventilation and physiologic factors at the time of VV ECMO decannulation and to determine if these factors have association with mechanical ventilation or ICU length of stay after ECMO decannulation. DESIGN: Multicenter, prospective cohort study. SETTING: Eleven ICUs in Australia. PATIENTS: Adult patients treated with VV ECMO from March 19, 2019, to September 20, 2020. INTERVENTIONS: Liberation from VV ECMO. RESULTS: Of 87 patients receiving VV ECMO, the median age was 49 years (interquartile range, 37–59 yr), 61 of 87 (70%) were male, and 52/87 (60%) had a diagnosis of acute respiratory distress syndrome. There were 24 of 87 patients (28%) who died prior to day 90. No patient required a second run of VV ECMO. In a multivariate models, a higher partial pressure of arterial carbon dioxide ( p < 0.01) and respiratory rate at the time of decannulation ( p = 0.01) were predictive of a longer duration of mechanical ventilation and ICU length of stay postdecannulation in survivors. Higher positive end-expiratory pressure at ECMO decannulation was associated with shorter duration of ICU length of stay post-ECMO decannulation in survivors ( p = 0.01). CONCLUSIONS: A higher partial pressure of arterial carbon dioxide and higher respiratory rate at ECMO decannulation were associated with increased duration of mechanical ventilation and increased duration of ICU stay postdecannulation, and increased positive end-expiratory pressure at decannulation was associated with decreased duration of ICU stay postdecannulation. Future research should further investigate these associations to establish the optimal ventilator settings and timing of liberation from VV ECMO.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.078
Threshold uncertainty score0.630

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.248
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueCritical Care ExplorationsSame topicMechanical Circulatory Support DevicesFrench-language works237,207