MétaCan
Menu
Back to cohort
Record W4225272072 · doi:10.5194/amt-2022-130

Development and Validation of a New In-Situ Technique to Measure Total Gaseous Chlorine in Ambient Air

2022· preprint· en· W4225272072 on OpenAlexafffund
Teles C. Furlani, P. M. Edwards, Tara F. Kahan, Cora J. Young

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEnvironmental Science
TopicWater Treatment and Disinfection
Canadian institutionsUniversity of SaskatchewanYork University
FundersH2020 European Research CouncilNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsAlfred P. Sloan Foundation
KeywordsChlorineChemistryCombustionDichloromethaneAnalytical Chemistry (journal)Mixing ratioSpectrometerDecompositionMixing (physics)Environmental chemistryPhysical chemistryOrganic chemistryOptics

Abstract

fetched live from OpenAlex

Abstract. Total gaseous chlorine (TClg) measurements can improve our understanding of unknown sources of Cl to the atmosphere. Existing techniques for measuring TClg have been limited to offline analysis of extracted filters and do not provide suitable temporal information on fast atmospheric process. We describe high time-resolution in-situ measurements of TClg by combusting ambient air over a heated platinum (Pt) substrate coupled to a cavity ring-down spectrometer (CRDS). The method relies on the complete decomposition of TClg to release Cl atoms that react to form HCl, for which detection by CRDS has been shown to be fast and reliable. The method was validated using custom organochlorine permeation devices (PDs) that generated gas-phase dichloromethane (DCM), 1-chlorobutane (CB), and 1,3-dichloropropene (DCP). The optimal conversion temperature and residence time through the high-temperature furnace was 825 °C and 1.5 seconds, respectively. Complete conversion was indicated by the near unity orthogonal distance regression analysis slope (±σ) of 0.996 ± 0.012, 1.048 ± 0.006, and 1.027 ± 0.061 for DCM, CB, and DCP, respectively. Breaking these strong C-Cl bonds represents a proof of concept for complete conversion of all similar or weaker bonds that characterize all other TClg. We applied this technique to both outdoor and indoor environments and found reasonable comparisons in ambient background mixing ratios with the sum of expected HCl from known Cl species. We measured the converted TClg in an indoor environment during cleaning activities and observed varying levels of TClg comparable to previous studies. The method validated here is capable of measuring in-situ TClg and has a broad range of applications to make routine TClg measurements in a variety of applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.233
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2022
Admission routes2
Has abstractyes

Explore more

Same topicWater Treatment and DisinfectionFrench-language works237,207