MétaCan
Menu
Back to cohort
Record W4225390811 · doi:10.1152/ajpregu.00013.2022

Pulsatile flow in venous perforators of the lower limb

2022· article· en· W4225390811 on OpenAlexaff
Kate N. Thomas, Travis D. Gibbons, Holly A. Campbell, James D. Cotter, André M. van Rij

Bibliographic record

VenueAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology · 2022
Typearticle
Languageen
FieldMedicine
TopicThermoregulation and physiological responses
Canadian institutionsUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
Fundersnot available
KeywordsPulsatile flowMedicineBlood flowUltrasoundMicrocirculationDiastoleAnkleCardiac cycleVeinCore (optical fiber)AnatomyBiomedical engineeringPerfusionHemodynamicsCardiologyInternal medicineBlood pressureMaterials scienceRadiology

Abstract

fetched live from OpenAlex

Teaching traditionally asserts that the arterial pressure pulse is dampened across the capillary bed to the extent that pulsatility is nonexistent in the venous circulation of the lower limbs. Herein, we present evidence of transmission of arterial pulsations across the capillary network into perforator veins in the lower limbs of healthy, heat-stressed humans. Perforator veins are connections from the superficial veins that drain into the deep veins. When assessed using ultrasound at rest, they infrequently demonstrate flow, and a pulsatile flow waveform is not described. We investigated perforator vein pulsatility in 10 young, healthy volunteers who underwent passive heating by +2°C core body temperature via a hot-water-perfused suit, and 5 who also underwent active heating by +2°C via low-intensity cycling while wearing the hot-water-perfused suit. At +0.5°C increments in temperature, blood velocity in an ankle perforator vein was measured using duplex ultrasound. In all perforators with heating, sustained flow was demonstrated, with a pulsatile waveform that was synchronous with the cardiac cycle. The maximum velocity was 30 ± 13 cm/s with passive heating and approximately half with active heating ( P = 0.04). The small veins of the skin at the ankle also demonstrated increased perfusion with pulsatility, seen with low-velocity microvascular imaging technology. We consider explanations for this pulsatility and conclude that it is propagated from the arterial inflow through the skin microcirculation as a result of increased dilatation and flow volume and that this is a normal response to increased skin blood flow.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.959
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.292
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of Physiology-Regulatory, Integrative and Comparative PhysiologySame topicThermoregulation and physiological responsesFrench-language works237,207