MétaCan
Menu
Back to cohort
Record W4226062045 · doi:10.1371/journal.pone.0265126

Enhanced protection face masks do not adversely impact thermophysiological comfort

2022· article· en· W4226062045 on OpenAlexafffund
Farzan Gholamreza, Anupama Vijaya Nadaraja, Abbas S. Milani, Kevin Golovin

Bibliographic record

VenuePLoS ONE · 2022
Typearticle
Languageen
FieldMedicine
TopicInfection Control and Ventilation
Canadian institutionsUniversity of TorontoUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
FundersMinistère de la Défense NationaleMitacs
KeywordsFace masksFace (sociological concept)MedicineCoronavirus disease 2019 (COVID-19)Internal medicine

Abstract

fetched live from OpenAlex

The World Health Organization has advocated mandatory face mask usage to combat the spread of COVID-19, with multilayer masks recommended for enhanced protection. However, this recommendation has not been widely adopted, with noncompliant persons citing discomfort during prolonged usage of face masks. And yet, a scientific understanding on how face mask fabrics/garment systems affect thermophysiological comfort remains lacking. We aimed to investigate how fabric/garment properties alter the thermal and evaporative resistances responsible for thermophysiological strain. We constructed 12 different layered facemasks (D1-D5, T1-T6, Q1) with various filters using commercially available fabrics. Three approaches were employed: (1) the evaporative and thermal resistances were measured in all the test face masks using the medium size to determine the effect of fabric properties; (2) the effect of face mask size by testing close-fitted (small), fitted (medium) and loose fitted (large) face mask T-6; (3) the effect of face mask fit by donning a large size face mask T-6, both loose and tightened using thermal manikin, Newton. ANOVA test revealed that the additional N95 middle layer filter has no significant effect on the thermal resistances of all the face masks, and evaporative resistances except for face masks T-2 and T-3 (P-values<0.05) whereas size significantly affected thermal and evaporative resistances (P-values<0.05). The correlation coefficient between the air gap size and the thermal and evaporative resistance of face masks T-6 were R2 = 0.96 and 0.98, respectively. The tight fit large face mask had superior performance in the dissipation of heat and moisture from the skin (P-values <0.05). Three-layer masks incorporating filters and water-resistant and antimicrobial/antiviral finishes did not increase discomfort. Interestingly, using face masks with fitters improved user comfort, decreasing thermal and evaporative resistances in direct opposition to the preconceived notion that safer masks decrease comfort.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.702
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.273
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuePLoS ONESame topicInfection Control and VentilationFrench-language works237,207