MétaCan
Menu
Back to cohort
Record W4226369073 · doi:10.3171/2022.1.jns212975

Immediate flow-diversion characteristics of a novel primarily bioresorbable flow-diverting stent

2022· article· en· W4226369073 on OpenAlexaff
Sandeep Muram, Ronan Corcoran, Jillian Cooke, Kendall Forrester, Elana Lapins, Rosalie Morrish, Osama Zahoor Ahmad Cheema, Mayank Goyal, Muneer Eesa, David Fiorella, John H. Wong, Chander Sadasivan, Alim P. Mitha

Bibliographic record

VenueJournal of neurosurgery · 2022
Typearticle
Languageen
FieldMedicine
TopicAortic aneurysm repair treatments
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsMedicineStentAneurysmRadiologyPulsatile flowAngiographySurgeryBiomedical engineeringCardiology

Abstract

fetched live from OpenAlex

OBJECTIVE: Flow-diverting stents with a resorbable component have significant theoretical benefits over full metal stents, although currently there are none in clinical use. In this study, the authors sought to determine the immediate flow-diversion characteristics of a novel primarily bioresorbable flow-diverting stent. METHODS: Bioresorbable stents were deployed into glass tube models to determine porosity and pore density. In vitro flow diversion behavior was evaluated using high frame rate angiography under pulsatile flow conditions in a patient-specific silicone aneurysm model treated with the resorbable stent as well as the Surpass Evolve stent. In vivo flow diversion was characterized by deployment into 20 rabbit saccular aneurysm models, and grading was based on the O'Kelly-Marotta scale and the 4F-flow diversion predictive score. RESULTS: Porosities and pore densities of the bioresorbable stent were in the flow-diverting range for all target vessel diameters. Quantified results of immediate angiography after placement of the bioresorbable stent into a silicone aneurysm model demonstrated greater flow diversion compared to the Evolve stent. Bioresorbable stent placement in saccular aneurysm models resulted in an immediate O'Kelly-Marotta grade of A3 or better and a 4F-flow diversion predictive score of 4 or better in all cases. CONCLUSIONS: The bioresorbable stent has immediate flow-diversion characteristics that are comparable to commercially available metal stents. Longer-term studies are underway to determine the ability of the resorbable fibers to act as a neointimal scaffold and result in long-term aneurysm occlusion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.000
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.247
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of neurosurgerySame topicAortic aneurysm repair treatmentsFrench-language works237,207