MétaCan
Menu
← Back to cohort
Record W4229334077 · doi:10.14740/jmc3841

Pseudoaneurysm Formation After “Preclose”-Assisted Impella Insertion in a Patient With Cardiogenic Shock

2022· article· en· W4229334077 on OpenAlexvenueno aff
Daniel Asemota, Zain Kassam, Christian Voto, Aditya Mangla, David Coven, Zoran Lasić

Bibliographic record

VenueJournal of Medical Cases · 2022
Typearticle
Languageen
FieldMedicine
TopicAcute Myocardial Infarction Research
Canadian institutionsnot available
Fundersnot available
KeywordsImpellaMedicineCardiogenic shockPseudoaneurysmPercutaneous coronary interventionCardiologyInternal medicinePercutaneousHematomaCardiac catheterizationMyocardial infarctionConventional PCISurgeryComplication

Abstract

fetched live from OpenAlex

The use of mechanical support devices such as the Impella CP (Abiomed, Danvers, MA) is a growing form of treatment for patients with cardiogenic shock (CS). Despite the increase in usage, there remains a dearth in literature regarding potential complications. Vascular complications such as pseudoaneurysms (PAs) are rare but important potential complications that can occur with use of the Impella. We present Impella-assisted percutaneous coronary intervention (PCI) in a patient with CS, "Preclosed" with the Perclose ProGlide (Abbott, Plymouth, MN) device complicated by development of a PA. A 62-year-old male patient with a history of diabetes and hypertension presented to our emergency room (ER) with chest pain and electrocardiogram (ECG) findings consistent with an acute anterior wall ST-elevation myocardial infarction (STEMI). This was further complicated by refractory CS. The patient was urgently taken to the cardiac catherization laboratory. After exchange of sequential dilators, a single Perclose device was used prior to the insertion of the Impella sheath. The patient then underwent a successful Impella-assisted PCI of his left anterior descending artery. Upon stabilization of hemodynamics, the patient was taken to the catheterization laboratory for Impella removal. After removal of Impella, imaging detected extravasation of contrast, without development of hematoma, later confirmed to be a PA via computed tomography (CT) scans and ultrasound Doppler imaging. The PA was successfully managed with injection of thrombin. The PA was likely caused by shearing forces of the dilators, the 14-F Impella sheath and foot of the device. We propose deploying the Perclose device earlier in the process of dilating the access site to avoid such complication. This is one of the first case reports that detail the occurrence and management of a PA with Impella insertion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0020.001
Scholarly communication0.0010.002
Open science0.0010.001
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.303
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Medical Cases→Same topicAcute Myocardial Infarction Research→French-language works237,207→