MétaCan
Menu
← Back to cohort
Record W4230190570 · doi:10.21203/rs.2.11328/v2

Complications and mortality of venovenous extracorporeal membrane oxygenation in the treatment of neonatal respiratory failure: a systematic review and meta-analysis

2019· review· en· W4230190570 on OpenAlexaboutno aff
Jing Xiong, Li Zhang, Lei Bao

Bibliographic record

VenueResearch Square · 2019
Typereview
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsnot available
Fundersnot available
KeywordsExtracorporeal membrane oxygenationMedicineMeta-analysisRespiratory failureIntensive care medicineExtracorporealAnesthesiaInternal medicine

Abstract

fetched live from OpenAlex

Abstract Background: Extracorporeal membrane oxygenation (ECMO) has been increasingly used for severe neonatal respiratory failure refractory to conventional treatments. To systematically evaluate the complications and mortality of venovenous ECMO in the treatment of neonatal respiratory failure, we performed a systematic review and meta-analysis of all the related studies. Methods: PubMed, Embase, and Cochrane Library were searched. The retrieval period was from the establishment of the database to February 2019. Two investigators independently screened articles according to the inclusion and exclusion criteria. The quality of article was assessed by the Newcastle-Ottawa scale (NOS). The meta-analysis was performed by Stata 15.0 software. Results: Four observational studies were included, with a total of 347 newborns. The overall mortality at hospital charge was 12% (5% - 18%) with a heterogeneity of I2 = 73.8% (p = 0.01). Two studies reported mortality during ECMO and after decannulation, with 10% (0.8% -19.2%) and 6.1% (2.6% - 9.6%) respectively. The most common complications associated with venovenous ECMO were: pneumothorax (20.6%), hypertension (20.4%), cannula dysfunction (20.2%), seizure (14.9%), renal failure requiring hemofiltration (14.7%), infectious complications (10.3%), thrombi (7.4%), intracranial hemorrhage or infarction (6.6%), hemolysis (5.3%), cannula site bleeding (4.4%), gastrointestinal bleeding (3.7%), oxygenator failure (2.8%), other bleeding events (2.8%), brain death (1.9%), and myocardial stun (0.9%). Conclusion: The overall mortality at discharge of venovenous ECMO in the treatment of neonatal respiratory failure was 12%. Although complications are frequent, the survival rate during hospitalization is still high. Further larger samples and higher quality of randomized controlled trials (RCT) are needed to clarify the efficacy and safety of this technique in the treatment of neonatal respiratory failure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.028
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.019
Threshold uncertainty score0.064

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.028
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0190.048
Bibliometrics0.0080.009
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0020.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.253
GPT teacher head0.426
Teacher spread0.173 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueResearch Square→Same topicMechanical Circulatory Support Devices→French-language works237,207→