MétaCan
Menu
Back to cohort
Record W4233854427 · doi:10.32920/ryerson.14656662

Investigating the Fracture Resistance of Bioactive Glass Coatings on Metallic Implants

2021· preprint· en· W4233854427 on OpenAlexafffund
Ali Matinmanesh

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchCalifornia HIV/AIDS Research Program
KeywordsMaterials scienceCoatingBioactive glassComposite materialSubstrate (aquarium)Shearing (physics)BoronResidual stressStrain energy release rateLaminated glassDelamination (geology)Fracture mechanicsLayer (electronics)

Abstract

fetched live from OpenAlex

Bioactive glasses have been used experimentally as coatings for medical implants because of their good osseointegration properties and ability to inhibit bacterial proliferation. However, the available literature lacks quantitative studies for characterizing their mechanical properties. This research postulates two fracture mechanics testing methodologies that facilitate measuring the nearly pure mode I (opening) and mode II (shearing) critical strain energy release rate (GIC, GIIC) of the coating/substrate system. Using these methodologies, the effects of coating thickness, glass composition and degradation on the GIC and GIIC of the system were evaluated. The developed mode I testing methodology was applied on a silicate bioactive glass/Ti6Al4V substrate system and it was found that increasing the coating thickness from 90 to 390 μm, decreased the measured GIC of the system significantly, from 6.2 to 2.5 J/m2. This decrease was found to be due to the increase in the residual stresses in the thicker coatings. The mode I testing methodology was then applied on two series of silica-based and borate-based glass coating, with increasing amounts of TiO2 incorporated, and it was observed that an increase in the content of TiO2 in the glasses resulted in an increase in the GIC for both the bulk glass and for the coating/substrate system. The borate-based series was found to have a closer CTE to the substrate compared to the silica counterpart, suggesting that use of such glasses as coatings can minimize the chances of delamination and cracking. Incorporating SrCO3 in a series of borate bioactive glass coating also proved to significantly increase the GIC and GIIC of the system. In order to study the effect of degradation, the borate bioactive glass coatings on Ti6Al4V substrates were immersed in deionized water for different time periods, dried and tested. It was found that after 17% weight loss of the glass, the GIC and GIIC of the coating/substrate system for all compositions decreased by at least 80%.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.231
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes2
Has abstractyes

Explore more

Same topicBone Tissue Engineering MaterialsFrench-language works237,207