Abstract

fetched live from OpenAlex

Geo-exchange systems are a sustainable alternative to conventional space conditioning systems due to their high operating efficiency, resulting in reduced energy consumption and greenhouse gas emissions. However, geo-exchange’s ability to penetrate the market has been throttled by large capital investments, resulting in undesirable payback periods. Optimized hybrid ground source heat pump systems (HGSHP) systems have been introduced as a remedy to overcome the current economic hurtles associated to the installation of geo-exchange systems. In both the literature, as well as in practice, there still remains potential for increased economic feasibility of this technology through integration of intelligent operational strategies. This paper presents a novel control methodology referred to as an off-peak ground pre-cool strategy, employing a time-of-use conscious operating logic which artificially pre-condition the system’s bore-field. Reducing peak power consumption is achieved by creating improved thermal characteristics during mid-peak/peak time-of-use operating brackets. A comprehensive numerical model was developed to characterize the operation of HGSHP systems for three real case studies. The mode implemented a base case set-point control scheme, used as a reference to assess the operational benefit of the proposed off-peak ground pre-cool control strategy. The preliminary analyses indicated operational cost savings of up to 16.4%, under specific pre-cool scheduling. The strategy indicated reductions in both carbon emission and peak power consumption of up t 19 15.0% and 58.5%, respectively. In all cases increasing cooling supplied by the hybrid geo 20 exchange system was indicated, with a maximum observed capacity increase of 43.7%.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.188
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.235
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes2
Has abstractyes

Explore more

Same topicGeothermal Energy Systems and ApplicationsFrench-language works237,207