MétaCan
Menu
Back to cohort
Record W4238215234 · doi:10.32920/ryerson.14665674

Feasibility of noninvasive thermometry in hyperthermia regime using harmonics generated by nonlinear ultrasound wave propagation

2021· preprint· en· W4238215234 on OpenAlexaff
B. Maraghechi

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsToronto Metropolitan UniversityLaurentian University
Fundersnot available
KeywordsHarmonicsUltrasoundMaterials scienceHarmonicBiomedical engineeringAcousticsAmplitudeMicrobubblesTemperature measurementHyperthermiaNonlinear systemOpticsPhysicsMedicineThermodynamics

Abstract

fetched live from OpenAlex

Hyperthermia is a cancer treatment modality that could be delivered as a stand-alone treatment or in conjunction with chemotherapy or radiation therapy. Noninvasive and real-time temperature monitoring of the heated tissue improves the efficacy and safety of the treatment. Ultrasound-based thermometry requires a temperature-sensitive acoustic parameter that can be used to estimate the temperature by tracking changes in that parameter during heating. This dissertation describes the experiments and simulations performed to obtain the temperature dependence of acoustic harmonics generated by nonlinear ultrasound propagation in several media including: water, an attenuating tissue-mimicking liquid, ex vivo bovine muscle tissues, and tissue-mimicking gel phantoms. The mechanisms of action of harmonic generation in water and in the attenuating liquid, made by a mixture of 90% glycerol and 10% water (by volume), as a function of temperature at various frequencies have been investigated using a temperature dependent Khokhlov–Zabolotskaya–Kuznetsov (KZK) nonlinear acoustic wave propagation model. The simulation results were compared with and validated by measurements. In water, the harmonic amplitudes decrease with increasing the temperature at low frequencies (1 and 3.3 MHz), while the opposite temperature dependence was observed at higher frequencies (13 and 20 MHz). The harmonic generation significantly increased with temperature in the tissue-mimicking liquid at both frequencies of 5 and 13 MHz. The temperature dependence of harmonics in tissue-mimicking gel phantoms and ex vivo bovine muscle tissues were measured using a commercial high-frequency ultrasound imaging system, and a new noninvasive ultrasound-based thermometry has been developed that is based on the backscattered energy of the harmonics. The sensitivity of this new thermometry technique to medium’s motion was studied and compared with the conventional echo-shift thermometry technique. Based on this study, it is suggested that noninvasive temperature estimation is feasible using acoustic harmonics with lower sensitivity to motion artifacts compared to the conventional echo-shift technique.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.259
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207