MétaCan
Menu
Back to cohort

Oscillating devices for airway clearance in people with cystic fibrosis

2014· review· en· W4241818435 on OpenAlexaff
Lisa Morrison, Jennifer L. Agnew

Bibliographic record

VenueCochrane Database of Systematic Reviews · 2014
Typereview
Languageen
Field
Topic
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsMedicineCystic fibrosisChest physiotherapyMucociliary clearanceAirwayMeta-analysisPsychological interventionInternal medicinePhysical therapySurgeryLung

Abstract

fetched live from OpenAlex

BACKGROUND: Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis. Oscillating devices generate intra- or extra-thoracic oscillations orally or external to the chest wall. Internally they create variable resistances within the airways, generating controlled oscillating positive pressure which mobilises mucus. Extra-thoracic oscillations are generated by forces outside the respiratory system, e.g. high frequency chest wall oscillation. OBJECTIVES: To identify whether oscillatory devices, oral or chest wall, are effective for mucociliary clearance and whether they are equivalent or superior to other forms of airway clearance in the successful management of secretions in people with cystic fibrosis. SEARCH METHODS: We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches and hand searches of relevant journals and abstract books of conference proceedings. Latest search of the Cystic Fibrosis Trials Register: 13 January 2014. SELECTION CRITERIA: Randomised controlled studies and controlled clinical studies of oscillating devices compared with any other form of physiotherapy in people with cystic fibrosis. Single-treatment interventions (therapy technique used only once in the comparison) were excluded. DATA COLLECTION AND ANALYSIS: Two authors independently applied the inclusion criteria to publications and assessed the quality of the included studies. MAIN RESULTS: The searches identified 68 studies with a total of 288 references; 35 studies (total of 1050 participants) met the inclusion criteria. Studies varied in duration from up to one week to one year; 20 of the studies were cross-over in design. The studies also varied in type of intervention and the outcomes measured, furthermore data were not published in sufficient detail in most of these studies, so meta-analysis was limited. Few studies were considered to have a low risk of bias in any domain. It is not possible to blind participants and clinicians to physiotherapy interventions, but 10 studies did blind the outcome assessors.Forced expiratory volume in one second was the most frequently measured outcome. One long-term study (seven months) compared oscillatory devices with either conventional physiotherapy or breathing techniques and found statistically significant differences in some lung function parameters in favour of oscillating devices. One study identified an increase in frequency of exacerbations requiring antibiotics whilst using high frequency chest wall oscillation when compared to positive expiratory pressure. There were some small but significant changes in secondary outcome variables such as sputum volume or weight, but not wholly in favour of oscillating devices. Participant satisfaction was reported in 15 studies but this was not specifically in favour of an oscillating device, as some participants preferred breathing techniques or techniques used prior to the study interventions. The results for the remaining outcome measures were not examined or reported in sufficient detail to provide any high level evidence. AUTHORS' CONCLUSIONS: There was no clear evidence that oscillation was a more or less effective intervention overall than other forms of physiotherapy; furthermore there was no evidence that one device is superior to another. The findings from one study showing an increase in frequency of exacerbations requiring antibiotics whilst using an oscillating device compared to positive expiratory pressure may have significant resource implications. More adequately-powered long-term randomised controlled trials are necessary and outcomes measured should include frequency of exacerbations, patient preference, adherence to therapy and general satisfaction with treatment. Increased adherence to therapy may then lead to improvements in other parameters, such as exercise tolerance and respiratory function. Additional evidence is needed to evaluate whether oscillating devices combined with other forms of airway clearance is efficacious in people with cystic fibrosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Direct model labels (unvalidated)

Per-model category and study-design labels from the labeling rounds. They are machine output, unvalidated, and the disagreement between models ships as data. No study design here is MEDLINE-validated yet.

Model armCategoriesStudy designConfidence
gemmano category
Domain: not available · Genre: Review
About the Canadian research system: no · About a Canadian topic: no
Systematic reviewlow
gptno category
Domain: not available · Genre: Review
About the Canadian research system: no · About a Canadian topic: no
Systematic reviewhigh
models agreeAgreement compares identical category sets and study designs across arms.

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.033
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.013
Threshold uncertainty score0.044

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.033
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0050.004
Bibliometrics0.0060.005
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0040.002
Insufficient payload (model declined to judge)0.0130.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.079
GPT teacher head0.368
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Labeled directly by 2 models reading the full record.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueCochrane Database of Systematic ReviewsFrench-language works237,207