MétaCan
Menu
Back to cohort

Evaluation of the Luminex xTAG Respiratory Viral Panel FAST v2 assay for detection of multiple respiratory viral pathogens in nasal and throat swabs in Vietnam

2017· preprint· en· W4244115939 on OpenAlexaff
Vu Thi Ty Hang, Nguyen Thi Han Ny, Tran My Phuc, Pham Thi Thanh Tam, Dang Thao Huong, Ho Dang Trung Nghia, Nguyen Tran Anh Vu, Pham Thi Hong Phuong, Nguyen Van Xang, Nguyen Thi Kim Dong, Phạm Như Hiệp, Nguyễn Văn Hùng, Tran Tinh Hien, Maia A. Rabaa, Guy Thwaites, Stephen Baker, Le Van Tan, H. Rogier van Doorn

Bibliographic record

VenueWellcome Open Research · 2017
Typepreprint
Languageen
FieldMedicine
TopicRespiratory viral infections research
Canadian institutionsMemorial University of Newfoundland
FundersUniversity of OxfordUniversiteit van AmsterdamWellcome TrustWellcome
KeywordsVirologyMultiplexRhinovirusRespiratory systemVirusThroatViral loadBiologyMedicineImmunologyInternal medicineBioinformatics

Abstract

fetched live from OpenAlex

<ns4:p>Background: Acute respiratory infections (ARI) are among the leading causes of hospitalization in children ≤5 years old. Rapid diagnostics of viral pathogens is essential to avoid unnecessary antibiotic treatment, thereby slowing down antibiotic-resistance. We evaluated the diagnostic performance of the Luminex xTAG Respiratory Viral Panel FAST v2 against viral specific PCR as reference assays for ARI in Vietnam.</ns4:p> <ns4:p>Methods: Four hundred and forty two nose and throat swabs were collected in viral transport medium, and were tested with Luminex xTAG Respiratory Viral Panel FAST v2. Multiplex RT-PCR and single RT-PCR were used as references. </ns4:p> <ns4:p>Results: Overall, viral pathogens were detected in a total count of 270/294 (91.8%, 95% CI 88.1-94.7) by the Luminex among reference assays, whilst 112/6336 (1.8%, 95% CI, 1.4-2.1) of pathogens were detected by the Luminex, but not by reference assays. Frequency of pathogens detected by Luminex and reference assays was 379 and 292, respectively. The diagnostic yield was 66.7% (295/442, 95%CI 62.1-71.1%) for the Luminex assay and 54.1% (239/442, 95% CI, 49.3-58.8%) for reference assays. The Luminex kit had higher yields for all viruses except influenza B virus, respiratory syncytial virus, and human bocavirus. High agreements between both methods [mean (range): 0.91 (0.83-1.00)] were found for 10/15 viral agents.</ns4:p> <ns4:p>Conclusions: The Luminex assay is a high throughput multiplex platform for rapid detection of common viral pathogens causing ARI. Although the current high cost may prevent Luminex assays from being widely used, especially in limited resource settings where ARI are felt most, its introduction in clinical diagnostics may help reduce unnecessary use of antibiotic prescription.</ns4:p>

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.051
metaresearch head score (Gemma)0.013
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow), Research integrity
Consensus categoriesMetaresearch
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.482
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0510.013
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0000.000
Open science0.0020.004
Research integrity0.0010.003
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.365
GPT teacher head0.479
Teacher spread0.115 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueWellcome Open ResearchSame topicRespiratory viral infections researchFrench-language works237,207