MétaCan
Menu
Back to cohort
Record W4246546902 · doi:10.21203/rs.3.rs-22980/v1

Performance of BioFire Array or QuickVue Influenza A+B Test versus a validation qPCR assay for detection of influenza A during a volunteer A/California/2009/H1N1 challenge study

2020· preprint· en· W4246546902 on OpenAlexfundno aff
David R. McIlwain, Han Chen, Maria Apkarian, Melton B. Affrime, Bonnie Bock, Kenneth H. Kim, Nilanjan Mukherjee, Garry P. Nolan, Monica McNeal

Bibliographic record

VenueResearch Square (Research Square) · 2020
Typepreprint
Languageen
FieldMedicine
TopicInfluenza Virus Research Studies
Canadian institutionsnot available
FundersCanadian Institutes of Health ResearchBiomedical Advanced Research and Development AuthorityNational Institutes of HealthU.S. Department of Health and Human Services
KeywordsContext (archaeology)MedicineVirologyConfidence intervalSeasonal influenzaInfluenza A virusVirusCoronavirus disease 2019 (COVID-19)Internal medicineBiologyInfectious disease (medical specialty)

Abstract

fetched live from OpenAlex

Abstract Background: Influenza places a significant burden on global health and economics. Individual case management and public health efforts to mitigate the spread of influenza are both strongly impacted by our ability to accurately and efficiently detect influenza viruses in clinical samples. Therefore, it is important to understand the performance characteristics of available assays to detect influenza in a variety of settings. We provide the first report of relative performance between two products marketed to streamline detection of influenza virus in the context of a highly controlled volunteer influenza challenge study. Methods: Nasopharyngeal swab samples were collected during a controlled A/California/2009/H1N1 influenza challenge study and analyzed using for detection of virus shedding using a validated qRT-PCR (qPCR) assay, a sample-to-answer qRT-PCR device (BioMerieux BioFire FilmArray RP), and an immunoassay based rapid test kit (Quidel QuickVue Influenza A+B Test).Results: Relative to qPCR, the sensitivity and specificity of the BioFire assay was 72.1% (63.7%-79.5%, 95% Confidence Interval (CI)) and 93.5% (89.3%-96.4%, 95% CI) respectively. For the QuickVue rapid test the sensitivity was 8.5% (4.8%-13.7%, 95% CI) and specificity was 99.2% (95.6%-100%, 95% CI).Conclusion: Relative to qPCR, the BioFire assay had superior performance compared to rapid test in the context of a controlled influenza challenge study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.028

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.295
GPT teacher head0.481
Teacher spread0.186 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueResearch Square (Research Square)Same topicInfluenza Virus Research StudiesFrench-language works237,207