MétaCan
Menu
Back to cohort
Record W4247336302 · doi:10.1177/155698451000500608

Thromboembolic Events in Patients on Extracorporeal Membrane Oxygenation without Anticoagulation

2010· article· en· W4247336302 on OpenAlexaff
Yoan Lamarche, Bryan Chow, Annie Bédard, Navreet Johal, Annemarie Kaan, Karin H. Humphries, Anson Cheung

Bibliographic record

VenueInnovations Technology and Techniques in Cardiothoracic and Vascular Surgery · 2010
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsProvidence Health Care
Fundersnot available
KeywordsMedicineExtracorporeal membrane oxygenationInterquartile rangeMembrane oxygenatorCardiogenic shockAnesthesiaThrombosisOxygenatorSurgeryPacked red blood cellsCardiologyCardiopulmonary bypassBlood transfusionMyocardial infarction

Abstract

fetched live from OpenAlex

Objective Heparinization is thought to be mandatory to avoid thromboembolic complications during venoarterial extracorporeal membrane oxygenation (VA-ECMO). However, bleeding complications are common. We report our experience of VA-ECMO without systemic anticoagulation. Methods A prospectively assembled database describing all ECMO cases from 2000 to 2008 was analyzed. A heparin coated circuit (Medtronic, Inc., Minneapolis, MN USA) and membrane oxygenator (Quadrox D Bioline oxygenator; MAQUET, Rastatt, Germany) were used in all cases. After the initiation of VA-ECMO support, all coagulation parameters were corrected. No further systemic maintenance anticoagulant was given, except at the time of weaning. Results Thirty-two patients received VA-ECMO support; 20 patients (62.5%) were males with a median age of 52.5 years (interquartile range, 40.4–61.1 years). Central and peripheral cannulations were 53% and 47%, respectively. Etiologies of cardiogenic shock were postcardiotomy (75%, n = 24) and as a support to cardiopulmonary resuscitation in 25% of cases (n = 8). Thirty-day mortality was 43.8%. Median duration of ECMO support was 46.3 hours (interquartile range, 26.8–87.8 hours). The median number of packed red blood cell transfusions was 18 ± 25. Complications include five patients (16%) with limb ischemia requiring intervention, 15 patients (46.9%) had acute renal failure, two patients had deep vein thrombosis, and two patients had intracardiac clots detected on echocardiograms. No patient had a cerebrovascular event. Incidence of membrane oxygenator failure was low, requiring replacement in three patients; no adverse event occurred during replacement. Fourteen patients (43.8%) were re-explored for bleeding. Fourteen patients (44%) were discharged home and were long-term survivors. Conclusions VA-ECMO support without systemic anticoagulation may reduce bleeding complications and transfusion requirement, without increasing the risk of thromboembolism.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.050
Threshold uncertainty score0.793

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.253
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations75
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueInnovations Technology and Techniques in Cardiothoracic and Vascular SurgerySame topicMechanical Circulatory Support DevicesFrench-language works237,207