MétaCan
Menu
Back to cohort
Record W4247623503 · doi:10.5383/ijtee.14.01.001

Wind Catcher and Trans-evaporative Cooling Residential Integration in Arid Region

2017· article· en· W4247623503 on OpenAlexvenueno aff
Isam Janajreh, Kamel Adouane, Mohammed Noorul Hussain

Bibliographic record

VenueInternational Journal of Thermal and Environmental Engineering · 2017
Typearticle
Languageen
FieldEnvironmental Science
TopicWind and Air Flow Studies
Canadian institutionsnot available
FundersMasdar Institute of Science and Technology
KeywordsEvaporative coolerRelative humidityWind speedEnvironmental scienceMeteorologyAtmospheric sciencesCooling towerHumidityAirflowMistMechanicsWater coolingThermodynamicsPhysics

Abstract

fetched live from OpenAlex

The wind catcher potential for providing occupants comfort conditions is been investigated under trans-evaporative cooling for two-level simple dwelling in arid region. The wind catcher runs on the reverse chimney concept in which the upper wind is captured (by means of passive or active louvers) and is impregnated with moisture that consequently reducing its temperature and increasing its density. This results in a cold downdraft stream in the tower which is used to the conditioning of the dwelling space. This work uses a high fidelity computational fluid dynamics (CFD) of multiple species and two-phase flow to examine the performance of the wind catcher subjected to water injection in the form of mist of 10micron droplet size. The air flow is governed by the none-isothermal Navies-stokes equations which are coupled with energy equation in a conjugated heat transfer in accounting to the inner building walls and the convective conditions for the rest of the building. The water droplet is governed by the discrete phase that also in direct coupling with the continuous phase representing the wind. Flow parameters including velocity, temperature, relative humidity and droplets dispersion are evaluated and their distribution is presented. The setup is tested at different regional conditions manifested in the incoming wind speed, present relative humidity level and temperature sensitivity. Results show that in the average UAE summer conditions (42o C and 50% R. humidity) the role of wind catcher in evaporative cooling was deemed unimportant. However under pre-dehumidification near 25% R. humidity a significant temperature drop of 10 o C and reasonable R. humidity of near 60% can be obtained when integrating wind catcher to isolated dwellings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.208
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Thermal and Environmental EngineeringSame topicWind and Air Flow StudiesFrench-language works237,207