Removal of Silicone Breast Implants and Review of Literature
Bibliographic record
Abstract
Silicone breast implants have a finite life span and may need changing over the lifetime of the patient. The experience with removing first- and second-generation implants is frustrating, because thick capsules often form, in association with rupture and spread of the silicone gel into the surrounding tissue. Different techniques have been employed to try and avoid an unnecessarily large incision, yet still control the dissection so that entire capsule and contained silicone can be removed en bloc. The authors describe a technique that facilitates atraumatic removal using an effective and time-saving vacuum principle.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.003 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.002 | 0.001 |
| Bibliometrics | 0.012 | 0.010 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.002 | 0.003 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.002 | 0.001 |
| Insufficient payload (model declined to judge) | 0.006 | 0.002 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".