MétaCan
Menu
Back to cohort
Record W4252249857 · doi:10.32920/ryerson.14640075

Assessment of Opto-mechanical Behavior of Biological Samples by Interferometry

2021· preprint· en· W4252249857 on OpenAlexafffund
Behrouz Soroushian, William M. Whelan, Michael C. Kolios

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsHealth PEIToronto Metropolitan University
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsMaterials scienceAttenuation coefficientThermoelastic dampingLaserInterferometryOpticsPhotoacoustic effectBiomedical engineeringGrüneisen parameterSIGNAL (programming language)Thermal expansionThermalComposite materialPhysics

Abstract

fetched live from OpenAlex

Optoacoustic imaging is a relatively novel biomedical imaging modality that relies on the absorption of light to create pressure transients that can be detected ultrasonically. In most scientific communications, the source of tissue contrast has been described as primarily optical. However, the thermomecahnical properties of tissue, as expressed through the Gruneisen coefficient, also affect the optoacoustic signal. To investigate the effect of thermomechanical tissue properties short pulses (~ 6.5 ns) from an optical parametric oscillator at 750 nm were used to irradiate coagulated and uncoagulated tissue-mimicking albumen phantoms, to emulate normal tissue and tissue that has been heated. The phantoms respond to the laser-induced stress by thermoelastic expansion. This thermomechanical behavior of the samples was assessed using an interferometric system capable of measuring transient displacements with a temporal resolution of less than 10 ns and a spatial resolution of < 10 nm. The experimental measurement allowed determination of the Gruneisen coefficient which is an important thermo-mechanical sample property that can affect generation of optoacoustic signals. An increase in the value of Gruneisen coefficient of 65% was measured when phantoms were coagulated compared to uncoagulated phantoms, consistent with the stiffening of the tissue mimicking material. This suggests that for thermal therapy the changes in the Gruneisen coefficient are also an important source of optoacoustic contrast.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.293
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes2
Has abstractyes

Explore more

Same topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207