MétaCan
Menu
Back to cohort
Record W4252348626 · doi:10.32920/ryerson.14649234

Frequency-Domain Synthetic Aperture Focusing Techniques for Imaging with Single-Element Focused Transducers

2021· preprint· en· W4252348626 on OpenAlexafffund
Elyas Shaswary

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsDeconvolutionImage resolutionTransducerOpticsImage qualityChirpPoint spread functionFilter (signal processing)Aperture (computer memory)AlgorithmSynthetic aperture radarSpatial frequencyFrequency domainComputer scienceSpeckle patternFocus (optics)Noise (video)PhysicsAcousticsArtificial intelligenceComputer visionImage (mathematics)Laser

Abstract

fetched live from OpenAlex

Synthetic aperture focusing techniques (SAFT) make the lateral spatial resolution of the conventional ultrasound imaging from a single-element focused transducer more uniform. In this work, two new frequency-domain SAFT (FD-SAFT) algorithms are proposed, which are based on 2D matched filtering techniques. The first algorithm is the FD-SAFT virtual disk source (FD-VDS) that treats the focus of a focused transducer as a finite sized virtual source and the diffraction effect in the far-field is accounted for in the image reconstruction. The second algorithm is the FD-SAFT deconvolution (FD-DC) that uses the simulated point spread function of the imaging system as a matched filter kernel in the image reconstruction. These algorithms were implemented for pulsed and linear frequency modulated chirp excitations. The performance of these algorithms was studied using a series of simulations and experiments, and it was compared with the conventional B-mode and time-domain virtual point source SAFT (TD-VPS) imaging techniques. The image quality was analyzed in terms of spatial resolution, sidelobe level, signal-to-noise ratio (SNR), contrast resolution, contrast-to- speckle ratio, and ex vivo tissue image quality. The results showed that the FD-VDS had the highest spatial resolution and FD-DC had the second highest spatial resolution. In addition, FD-DC had generally the highest SNR. The computation run time of the proposed methods was significantly lower than the TD-VPS. Furthermore, chirp excitation improves the SNR of all methods by about 8 dB without significantly affecting the spatial resolution and sidelobe level. Thus, the FD-VDS and FD-DC methods offer efficient solutions to make the spatial resolution of conventional B-mode imaging more uniform.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.212
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes2
Has abstractyes

Explore more

Same topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207