MétaCan
Menu
Back to cohort
Record W4253240883 · doi:10.1148/radiology.13130609

Pulmonary Ultrashort Echo Time<sup>19</sup>F MR Imaging with Inhaled Fluorinated Gas Mixtures in Healthy Volunteers: Feasibility

2013· article· en· W4253240883 on OpenAlexaffabout
Marcus J. Couch, Iain Ball, Tao Li, Matthew S. Fox, Shalyn Littlefield, Birubi Biman, Mitchell S. Albert

Bibliographic record

VenueRadiology · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsNOSM UniversityThunder Bay Regional Health Sciences CentreLakehead UniversityMcMaster UniversityThunder Bay Regional Research Institute
Fundersnot available
KeywordsMedicineEcho (communications protocol)Nuclear medicineNuclear magnetic resonanceRadiology

Abstract

fetched live from OpenAlex

Purpose To perform static breath-hold fluorine 19 (19F) three-dimensional (3D) ultrashort echo time (UTE) magnetic resonance (MR) imaging of the lungs in healthy volunteers by using a mixture of 79% perfluoropropane (PFP) and 21% O2. Materials and Methods This study protocol was approved by the local research ethics board and by Health Canada. All volunteers provided written informed consent. Ten healthy volunteers underwent MR imaging at 3.0 T. Fluorine 19 3D UTE MR images were acquired during a 15-second breath hold according to one of two breathing protocols: protocol A, a 1-L inhalation of a mixture of 79% PFP and 21% O2, and protocol B, continuous breathing from a 5-L bag of a mixture of 79% PFP and 21% O2 followed by a 1-L inhalation of the same PFP-O2 mixture from a separate bag and a subsequent breath hold. The signal-to-noise ratio (SNR) was measured in the three most central image sections and was compared between breathing protocols by using an unpaired t test. Results Overall, the SNR was significantly greater for breathing protocol B (continuous breathing) than for breathing protocol A (single breath) (P = .018). The mean SNRs were 18 ± 6 (standard deviation) and 32 ± 6 for images acquired by using breathing protocols A and B, respectively. Breathing protocol B improves SNR by "washing out" the air from the lungs and increasing the PFP concentration prior to 19F imaging. Conclusion This study demonstrates the feasibility of 19F 3D UTE static breath-hold MR imaging of human lungs with inert fluorinated gases. © RSNA, 2013

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.884
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.265
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueRadiologySame topicAtomic and Subatomic Physics ResearchFrench-language works237,207