MétaCan
Menu
Back to cohort
Record W4255543565 · doi:10.26434/chemrxiv.14574315.v1

Template Instrumentation for "Accurate Constant via Transient Incomplete Separation" (ACTIS)

2021· preprint· en· W4255543565 on OpenAlexaff
Jean‐Luc Rukundo, Sven Kochmann, Tong Ye Wang, Nikita A. Ivanov, J. C. Yves Le Blanc, Boris I. Gorin, Sergey N. Krylov

Bibliographic record

VenueChemRxiv · 2021
Typepreprint
Languageen
FieldPhysics and Astronomy
TopicNMR spectroscopy and applications
Canadian institutionsAlphora Research (Canada)York University
Fundersnot available
KeywordsFluidicsInstrumentation (computer programming)Transient (computer programming)SIGNAL (programming language)DiffusionBiological systemComputer scienceMechanicsControl theory (sociology)PhysicsArtificial intelligenceAerospace engineeringThermodynamicsEngineering

Abstract

fetched live from OpenAlex

ACTIS is a new method for finding the equilibrium dissociation constant K d of a protein–small molecule complex based on transient incomplete separation of the complex from the unbound small molecule in a capillary. This separation is caused by differential transverse diffusion of the complex and the small molecule in a pressure-driven flow. The advection-diffusion processes underlying ACTIS can be described by a system of partial differential equations allowing for a virtual ACTIS instrument to be built and ACTIS to be studied in silico. The previous in-silico studies show that large variations in the fluidic system geometry do not affect the accuracy of K d determination, thus, proving that ACTIS is conceptually accurate. The conceptual accuracy does not preclude, however, instrumental inaccuracy caused by run-to-run signal drifts. Here we report on assembling a physical ACTIS instrument with a fluidic system that mimics the virtual one and proving the absence of signal drifts. Furthermore, we confirmed method ruggedness by assembling a second ACTIS instrument and comparing the results of experiments performed with both instruments in parallel. Despite some differences between the instruments and, accordingly, significant differences in their respective separagrams, we found that the K d values determined for identical samples with these instruments were equal. Conclusively, the fluidic system presented here can serve as a template for reliable ACTIS instrumentation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0020.002
Open science0.0030.002
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.0040.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.361
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueChemRxivSame topicNMR spectroscopy and applicationsFrench-language works237,207