MétaCan
Menu
Back to cohort

The use of ultrasound guidance for perioperative neuraxial and peripheral nerve blocks in children

2019· review· en· W4256119087 on OpenAlexaff
Joanne Guay, Santhanam Suresh, Sandra L. Kopp

Bibliographic record

VenueCochrane Database of Systematic Reviews · 2019
Typereview
Languageen
FieldMedicine
TopicAnesthesia and Pain Management
Canadian institutionsUniversité LavalUniversité du Québec en Abitibi-TémiscamingueUniversité de Sherbrooke
Fundersnot available
KeywordsMedicineNeuraxial blockadeUltrasoundNerve blockPerioperativeAnesthesiaSurgeryRandomized controlled trialRadiology

Abstract

fetched live from OpenAlex

Background The use of ultrasound guidance for regional anaesthesia has become popular over the past two decades. However, it is not recognized by all experts as an essential tool, perhaps because it is unclear whether ultrasound reduces the risk of severe neurological complications, and the cost of an ultrasound machine (USD 22,000) is substantially higher than the cost of other tools. This review was published in 2016 and updated in 2019. Objectives To determine whether ultrasound guidance offers any clinical advantage when neuraxial and peripheral nerve blocks are performed in children in terms of decreasing failure rate or the rate of complications. Search methods We searched CENTRAL, MEDLINE, Embase, and two trial registers up to March 2018 together with reference checking to identify additional studies and contacted study authors to obtain additional trial information. Selection criteria We included all parallel randomized controlled trials that evaluated the effects of ultrasound guidance used when a regional blockade technique was performed in children. We included studies performed in children (≤ 18 years of age) undergoing any type of surgical procedure (open or laparoscopic), for which a neuraxial (spinal, epidural, caudal, or combined spinal and epidural) or peripheral nerve block (any peripheral nerve block including fascial (fascia iliaca, transversus abdominis plane, rectus sheath blocks) or perivascular blocks), for surgical anaesthesia (alone or in combination with general anaesthesia) or for postoperative analgesia, was performed with ultrasound guidance. We excluded studies in which regional blockade was used to treat chronic pain. We included studies in which ultrasound guidance was used to perform the technique in real time (in‐plane or out‐of‐plane), as pre‐scanning before the procedure or to evaluate the spread of the local anaesthetic so the position of the needle could be adjusted or the block complemented. For control groups, any other technique used to perform the block including landmarks, loss of resistance (air or fluid), click, paraesthesia, nerve stimulator, transarterial, or infiltration was accepted. Data collection and analysis We used the standard methodological procedures expected by Cochrane. Our primary outcomes were failed blocks, pain scores at one hour after surgery, and block duration. Secondary outcomes included time to perform the block, number of needle passes, and minor and major complications. We used GRADE to assess the quality of evidence for each outcome. Main results We included 33 trials with a total of 2293 participants from 0.9 to 12 (mean or median) years of age. Most trials were at low risk of selection, detection, attrition, and reporting bias, however the lack of blinding of participants and personnel caring for participants resulted in 25 trials being judged as at high or unclear risk of bias. We identified five ongoing trials. Ultrasound guidance probably reduces the risk of failed block (risk difference (RD) −0.16, 95% confidence interval (CI) −0.25 to −0.07; 22 trials; 1789 participants; moderate‐quality evidence). When ultrasound guidance was used, there was a small to moderate reduction in pain one hour after surgery, equivalent to a reduction of 1.3 points on the revised Bieri FACES pain scale (scale; 0 = no pain, 10 = maximal pain) (standardized mean difference (SMD) −0.41, 95% CI −0.74 to −0.07 (medium effect size); 15 trials; 982 participants; moderate‐quality evidence). Ultrasound guidance increases block duration by the equivalent of 42 minutes (SMD 1.24, 95% CI 0.72 to 1.75; 10 trials; 460 participants; high‐quality evidence). There is probably little or no difference in the time taken to perform the block (SMD −0.46, 95% CI −1.06 to 0.13; 9 trials; 680 participants; moderate‐quality evidence). It is uncertain whether the number of needle passes required is reduced with the use of ultrasound guidance (SMD −0.63, 95% CI −1.08 to −0.18; 3 trials; 256 participants; very low‐quality evidence). There were no occurrences of major complications in either the intervention or control arms of the trials (cardiac arrest from local anaesthetic toxicity (22 trials; 1576 participants; moderate‐quality evidence); lasting neurological injury (19 trials; 1250 participants; low‐quality evidence)). There may be little of no difference in the risk of bloody puncture (RD −0.02, 95% CI −0.05 to 0.00; 13 trials; 896 participants; low‐quality evidence) or transient neurological injury (RD −0.00, 95% CI −0.01 to 0.01; 18 trials; 1230 participants; low‐quality evidence). There were no occurrences of seizure from local anaesthetic toxicity (22 trials; 1576 participants; moderate‐quality evidence) or block infections without neurological injury (18 trials; 1238 participants; low‐quality evidence). Authors' conclusions Ultrasound guidance for regional blockade in children probably decreases the risk of failed block. It increases the duration of the block and probably decreases pain scores at one hour after surgery. There may be little or no difference in the risks of some minor complications. The five ongoing studies may alter the conclusions of the review once published and assessed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Direct model labels (unvalidated)

Per-model category and study-design labels from the labeling rounds. They are machine output, unvalidated, and the disagreement between models ships as data. No study design here is MEDLINE-validated yet.

Model armCategoriesStudy designConfidence
gemmano category
Domain: not available · Genre: Review
About the Canadian research system: no · About a Canadian topic: no
Systematic reviewlow
gptno category
Domain: not available · Genre: Review
About the Canadian research system: no · About a Canadian topic: no
Systematic reviewhigh
models agreeAgreement compares identical category sets and study designs across arms.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.316
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0060.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.120
GPT teacher head0.367
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Labeled directly by 2 models reading the full record.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations44
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueCochrane Database of Systematic ReviewsSame topicAnesthesia and Pain ManagementFrench-language works237,207