MétaCan
Menu
Back to cohort
Record W4280571008 · doi:10.1371/journal.pone.0268340

Multicenter international assessment of a SARS-CoV-2 RT-LAMP test for point of care clinical application

2022· article· en· W4280571008 on OpenAlexafffundabout
Suying Lü, David Duplat, Paula Benitez-Bolivar, Cielo León, Stephany D. Villota, Eliana Veloz-Villavicencio, Valentina Arévalo, Katariina Jaenes, Yuxiu Guo, Seray Cicek, Lucas Robinson, Philippos Peidis, Joel D. Pearson, James R. Woodgett, Tony Mazzulli, Patricio Ponce, Silvia Restrepo, John Morán González, Adriana Bernal, Marcela Guevara‐Suarez, Keith Pardee, Varsovia Cevallos, Camila González, Rod Bremner

Bibliographic record

VenuePLoS ONE · 2022
Typearticle
Languageen
FieldEngineering
TopicBiosensors and Analytical Detection
Canadian institutionsUniversity Health NetworkSinai Health SystemLunenfeld-Tanenbaum Research InstituteUniversity of WaterlooUniversity of Toronto
FundersKrembil FoundationUniversity of TorontoInternational Development Research Centre
KeywordsLoop-mediated isothermal amplificationPoint of careSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Point-of-care testingVirologyDetection limitMedicineCoronavirus disease 2019 (COVID-19)PandemicBiologyChemistryImmunologyInfectious disease (medical specialty)ChromatographyPathologyDiseaseDNA

Abstract

fetched live from OpenAlex

Continued waves, new variants, and limited vaccine deployment mean that SARS-CoV-2 tests remain vital to constrain the coronavirus disease 2019 (COVID-19) pandemic. Affordable, point-of-care (PoC) tests allow rapid screening in non-medical settings. Reverse-transcription loop-mediated isothermal amplification (RT-LAMP) is an appealing approach. A crucial step is to optimize testing in low/medium resource settings. Here, we optimized RT-LAMP for SARS-CoV-2 and human β-actin, and tested clinical samples in multiple countries. "TTTT" linker primers did not improve performance, and while guanidine hydrochloride, betaine and/or Igepal-CA-630 enhanced detection of synthetic RNA, only the latter two improved direct assays on nasopharygeal samples. With extracted clinical RNA, a 20 min RT-LAMP assay was essentially as sensitive as RT-PCR. With raw Canadian nasopharygeal samples, sensitivity was 100% (95% CI: 67.6% - 100%) for those with RT-qPCR Ct values ≤ 25, and 80% (95% CI: 58.4% - 91.9%) for those with 25 < Ct ≤ 27.2. Highly infectious, high titer cases were also detected in Colombian and Ecuadorian labs. We further demonstrate the utility of replacing thermocyclers with a portable PoC device (FluoroPLUM). These combined PoC molecular and hardware tools may help to limit community transmission of SARS-CoV-2.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.680
Threshold uncertainty score0.204

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.322
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2022
Admission routes3
Has abstractyes

Explore more

Same venuePLoS ONESame topicBiosensors and Analytical DetectionFrench-language works237,207