MétaCan
Menu
Back to cohort
Record W4281558402 · doi:10.1016/j.jmbbm.2022.105294

Fiber orientation downsampling compromises the computation of white matter tract-related deformation

2022· article· en· W4281558402 on OpenAlexaff
Zhou Zhou, Teng Wang, Daniel Jörgens, Xiaogai Li

Bibliographic record

VenueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2022
Typearticle
Languageen
FieldMedicine
TopicAutomotive and Human Injury Biomechanics
Canadian institutionsToronto Western HospitalUniversity Health Network
FundersChina Scholarship CouncilVetenskapsrådetKungliga Tekniska HögskolanSwedish Foundation for International Cooperation in Research and Higher Education
KeywordsDiffusion MRIVoxelFiber tractUpsamplingOrientation (vector space)White matterArtificial intelligenceComputer scienceComputer visionGeometryMathematicsMagnetic resonance imagingMedicineRadiology

Abstract

fetched live from OpenAlex

Incorporating neuroimaging-revealed structural details into finite element (FE) head models opens vast new opportunities to better understand brain injury mechanisms. Recently, growing efforts have been made to integrate fiber orientation from diffusion tensor imaging (DTI) into FE models to predict white matter (WM) tract-related deformation that is biomechanically characterized by tract-related strains. Commonly used approaches often downsample the spatially enriched fiber orientation to match the FE resolution with one orientation per element (i.e., element-wise orientation implementation). However, the validity of such downsampling operation and corresponding influences on the computed tract-related strains remain elusive. To address this, the current study proposed a new approach to integrate voxel-wise fiber orientation from one DTI atlas (isotropic resolution of 1 mm3) into FE models by embedding orientations from multiple voxels within one element (i.e., voxel-wise orientation implementation). By setting the responses revealed by the newly proposed voxel-wise orientation implementation as the reference, we evaluated the reliability of two previous downsampling approaches by examining the downsampled fiber orientation and the computationally predicted tract-related strains secondary to one concussive impact. Two FE models with varying element sizes (i.e., 6.4 ± 1.6 mm and 1.3 ± 0.6 mm, respectively) were incorporated. The results showed that, for the model with a large voxel-mesh resolution mismatch, the downsampled element-wise fiber orientation, with respect to its voxel-wise counterpart, exhibited an absolute deviation over 30° across the WM/gray matter interface and the pons regions. Accordingly, this orientation deviation compromised the computation of tract-related strains with normalized root-mean-square errors up to 30% and underestimated the peak tract-related strains up to 10%. For the other FE model with finer meshes, the downsampling-induced effects were lower, both on the fiber orientation and tract-related strains. Taken together, the voxel-wise orientation implementation is recommended in future studies as it leverages the DTI-delineated fiber orientation to a larger extent than the element-wise orientation implementation. Thus, this study yields novel insights on integrating neuroimaging-revealed fiber orientation into FE models and may better inform the computation of WM tract-related deformation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.037
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0090.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.293
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsSame topicAutomotive and Human Injury BiomechanicsFrench-language works237,207