MétaCan
Menu
Back to cohort
Record W4281763839 · doi:10.26434/chemrxiv-2022-3dp7v

Automated Device for Multi-Stage Paper-Based Assays Enabled by an Electroosmotic Pumping Valve

2022· preprint· en· W4281763839 on OpenAlexafffund
Baruch Rofman, Rawi Naddaf, Maya Bar Dolev, Tal Avi-Gefen, Nadav Ben-Assa, Naama Geva‐Zatorsky, Moran Bercovici

Bibliographic record

VenueChemRxiv · 2022
Typepreprint
Languageen
FieldEngineering
TopicBiosensors and Analytical Detection
Canadian institutionsCanadian Institute for Advanced Research
FundersIsrael Science FoundationCanadian Institute for Advanced Research
KeywordsMicrofluidicsMaterials scienceElectrodeFluidicsComputer scienceOptoelectronicsNanotechnologyElectrical engineeringEngineeringChemistry

Abstract

fetched live from OpenAlex

This work presents the use of electroosmotic flow generation in porous media in combination with a hydrophobic air gap to create a controllable valve capable of operating in either finite dosing or continuous flow mode, enabling the implementation of multi-step biochemical assays on paper-based devices. A hierarchical superhydrophobic surface placed between two paper pads creates an air gap, keeping the valve nominally closed. To open the valve, a pair of electrodes are activated to generate electroosmotic pressure that overcomes the barrier. The study provides an experimentally validated model describing the governing parameters, and a detailed investigation of the closed valve stability. From these, a straightforward design for a compact and fully automated device is derived. The design is based on paper pads placed on printed circuit boards (PCB), equipped with heating and actuation electrodes and additional power and logic capabilities. The device is applied to the detection of SARS-CoV-2 sequences directly from raw saliva samples, using loop-mediated isothermal amplification (LAMP) requiring sample lysis followed by enzymatic deactivation and sample distribution to multiple amplification pads. Since PCB costs scale favorably with mass production, we believe that this approach could lead to low-cost diagnostic devices with the sensitivity of amplification methods.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.288
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueChemRxivSame topicBiosensors and Analytical DetectionFrench-language works237,207