MétaCan
Menu
Back to cohort
Record W4281864708 · doi:10.1088/1361-6560/ac7430

Improving coronary ultrafast Doppler angiography using fractional moving blood volume and motion-adaptive ensemble length

2022· article· en· W4281864708 on OpenAlexafffund
Naiyuan Zhang, Minh B. Nguyen, Luc Mertens, David J. Barron, Olivier Villemain, Jérôme Baranger

Bibliographic record

VenuePhysics in Medicine and Biology · 2022
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsHospital for Sick ChildrenUniversity of Toronto
FundersCanadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada
KeywordsImaging phantomAttenuationBlood flowRegion of interestBiomedical engineeringDoppler effectMedicineNuclear medicineRadiologyPhysicsOptics

Abstract

fetched live from OpenAlex

Abstract Coronary microperfusion assessment is a key parameter for understanding cardiac function. Currently, coronary ultrafast Doppler angiography is the only non-invasive clinical imaging technique able to assess coronary microcirculation quantitatively in humans. In this study, we propose to use fractional moving blood volume (FMBV), proportional to the red blood cell concentration, as a metric for perfusion. FMBV compares the power Doppler in a region of interest (ROI) inside the myocardium to the power Doppler of a reference area in the heart chamber, fully filled with blood. This normalization gives then relative values of the ROI blood filling. However, due to the impact of ultrasound attenuation and elevation focus on power Doppler values, the reference area and the ROI need to be at the same depth to allow this normalization. This condition is rarely satisfied in vivo due to the cardiac anatomy. Hereby, we propose to locally compensate the attenuation between the ROI and the reference, by measuring the attenuation law on a phantom. We quantified the efficiency of this approach by comparing FMBV with and without compensation on a flow phantom. Compensated FMBV was able to estimate the ground-truth FMBV with less than 5% variation. This method was then adapted to the in vivo case of myocardial perfusion imaging during heart surgery on human neonates. The translation from in vitro to in vivo required an additional clutter filtering step to ensure that blood signals could be correctly identified in the fast-moving myocardium. We applied the singular value decomposition filter on temporal sliding windows whose lengths were a function of myocardium motion. This motion-adaptive temporal sliding window approach was able to improve blood and tissue separation in terms of contrast-to-noise ratio, as compared to well-established constant-length sliding window approaches. Therefore, compensated FMBV and singular value decomposition assisted with motion-adaptive temporal sliding windows improves the quantification of blood volume in coronary ultrafast Doppler angiography.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.077
GPT teacher head0.314
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicUltrasound Imaging and ElastographyFrench-language works237,207