Vibrational characteristic of heart stent using finite element model
Bibliographic record
Abstract
Heart stents are widely implemented for those patients who suffer from chronic heart diseases. The primary failure of this biomedical device is its collapse during the operation. The most common sources of this failure come from the nature of the stent material and surgery conditions. The focus of the paper is on the vibrational behavior of the integrated part of the artery and stent by simulating the operating condition using a finite element model. Modal analysis of the proposed model is performed to determine the natural frequencies and corresponding mode shapes of the system. In addition, harmonic analysis of the model is performed to derive the kinematic characteristics, including displacement, velocity, acceleration, and directional stresses, by considering the effect of blood pressure. Finally, the spectral analysis of the complex is applied to investigate the influence of random vibrational excitations on the system by using power spectral density (PSD) analysis.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".