MétaCan
Menu
Back to cohort
Record W4285324645 · doi:10.2196/35396

Diagnosis of Atrial Fibrillation Using Machine Learning With Wearable Devices After Cardiac Surgery: Algorithm Development Study

2022· article· en· W4285324645 on OpenAlexvenueno aff
Daisuke Hiraoka, Tomohiko Inui, Eiryo Kawakami, Megumi Oya, Ayumu Tsuji, Koya Honma, Yohei Kawasaki, Yoshihito Ozawa, Yuki Shiko, Hideki Ueda, Hiroki Kohno, Kaoru Matsuura, Michiko Watanabe, Yasunori Yakita, Goro Matsumiya

Bibliographic record

VenueJMIR Formative Research · 2022
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsnot available
FundersJapan Society for the Promotion of Science
KeywordsPhotoplethysmogramAtrial fibrillationMedicineWearable computerCardiologyPulse (music)Internal medicineAlgorithmComputer scienceComputer visionTelecommunicationsEmbedded system

Abstract

fetched live from OpenAlex

BACKGROUND: Some attempts have been made to detect atrial fibrillation (AF) with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. OBJECTIVE: This study is the second part of a 2-phase study aimed at developing a method for immediate detection of paroxysmal AF, using a wearable device with built-in photoplethysmography (PPG). The objective of this study is to develop an algorithm to immediately diagnose AF by an Apple Watch equipped with a PPG sensor that is worn by patients undergoing cardiac surgery and to use machine learning on the pulse data output from the device. METHODS: A total of 80 patients who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative AF, using a telemetry-monitored electrocardiogram (ECG) and an Apple Watch. AF was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on the pulse rate data output from the Apple Watch. RESULTS: One of the 80 patients was excluded from the analysis due to redness caused by wearing the Apple Watch. Of 79 patients, 27 (34.2%) developed AF, and 199 events of AF including brief AF were observed. Of them, 18 events of AF lasting longer than 1 hour were observed, and cross-correlation analysis showed that pulse rate measured by Apple Watch was strongly correlated (cross-correlation functions [CCF]: 0.6-0.8) with 8 events and very strongly correlated (CCF>0.8) with 3 events. The diagnostic accuracy by machine learning was 0.9416 (sensitivity 0.909 and specificity 0.838 at the point closest to the top left) for the area under the receiver operating characteristic curve. CONCLUSIONS: We were able to safely monitor pulse rate in patients who wore an Apple Watch after cardiac surgery. Although the pulse rate measured by the PPG sensor does not follow the heart rate recorded by telemetry-monitored ECGs in some parts, which may reduce the accuracy of AF diagnosis by machine learning, we have shown the possibility of clinical application of using only the pulse rate collected by the PPG sensor for the early detection of AF.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.072
Threshold uncertainty score0.479

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.103
GPT teacher head0.404
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Formative ResearchSame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207