MétaCan
Menu
← Back to cohort
Record W4285464809 · doi:10.32920/ryerson.14644314

A biomechanical investigation of the surface stress of a synthetic femur using infrared thermography validated by strain gauge measurements

2021· preprint· en· W4285464809 on OpenAlexaff
Suraj Shah

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsToronto Metropolitan UniversityUniversity of Toronto
Fundersnot available
KeywordsThermographyStrain gaugeThermoelastic dampingMaterials scienceFemurStrain (injury)BiomechanicsStress (linguistics)OrthodonticsInfraredStructural engineeringBiomedical engineeringComposite materialMedicineSurgeryAnatomyThermalEngineeringOpticsPhysics

Abstract

fetched live from OpenAlex

As the North American population ages, there will be a massive increase in musculoskeletal impairments because these problems are most common in the elderly. A very common condition is osteoporosis, which can result in fractures. Therefore, the need for improved orthopaedic fracture repair implants is vital. Currently, the two main approaches in studying orthopaedic implants are strain gauge measurements and finite element modelling. This study introduces and validates a relatively new, non-destructive approach in analysing stress patterns in a biomechanics application. Lock-in infrared (IR) thermography calibrated with strain gauges was used to investigate the stress and strain patterns of a synthetic femur under dynamic loading. The femur was instrumented with strain gauges and tested using axial average forces of 1500N, 1800N, and 2100N at an adduction angle of 7 degrees to simulate the single-legged stance phase of walking. Three dimensional surface stress maps were obtained using an IR thermography versus strain gauge data with a Pearson correlation of R² = 0.99 and a slope ranging from 0.99 to 1.08, based on thermoelastic coefficient (Km) ranging from 1.067 x 10⁻⁵/MPa to 1.16 x 10⁻⁵/MPa, for the line of best fit. IR thermography detected bone peak stresses on the superior-posterior side of the femoral neck of 91.2MPa (at 1500 N), 96.0Mpa (at 1800 N), and 103.5MPa (at 2100 N). There was strong correlation between IR measured stresses and force along the anterior (R² = 0.87 to 0.99), posterior (R² = 0.81 to 0.99) and lateral (R² = 0.89 to 0.99) surface. This is the first study to provide an experimentally validated three dimensional stress map of a synthetic femur using IR thermography.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.282
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes1
Has abstractyes

Explore more

Same topicOrthopaedic implants and arthroplasty→French-language works237,207→