MétaCan
Menu
Back to cohort
Record W4285490841 · doi:10.1371/journal.pone.0270328

Open source surgical fracture table for digitally distributed manufacturing

2022· article· en· W4285490841 on OpenAlexaff
Jennifer K. Bow, Nicole Gallup, Seyyed Ali Sadat, Joshua M. Pearce

Bibliographic record

VenuePLoS ONE · 2022
Typearticle
Languageen
FieldEngineering
TopicAnatomy and Medical Technology
Canadian institutionsWestern University
Fundersnot available
KeywordsTable (database)3D printingOpen source3d printedOperating tableComputer scienceComputer hardwareMechanical engineeringSoftwareEngineeringOperating systemBiomedical engineeringDatabase

Abstract

fetched live from OpenAlex

Roughly a third of the surgical procedures the World Bank is prioritizing as essential and cost-effective are orthopedic procedures. Yet in much of the developing world, prohibitive costs are a substantial barrier to universal access. One area where this is clear is surgical fracture tables, which generally cost >US$200,000 new. With the advent of 3-D printing, a new way to reduce medical equipment costs is to use open source hardware licensed designs to fabricate digitally-distributed manufactured medical hardware. That approach is applied here to make surgical tables more accessible. This study describes the design and manufacture of an open source surgical fracture table that uses materials that are widely available worldwide with specialty components being 3-D printed. The bill of materials and assembly instructions are detailed and the fracture table is validated to perform mechanically to specifications. Using an open source desktop RepRap-class 3-D printer, the components can be printed in a little over a week of continuous printing. Including the 3-D printed parts, the open source fracture table can be constructed for under US$3,000 in material costs, representing a 98.5% savings for commercial systems, radically increasing accessibility. The open source table can be adjusted 90-116 cm in height, tilted from +/-15 degrees, the leg height ranges from 31 to 117 cm, the arm supports and foot holder both have a 180-degree range, the foot position has a 54 cm range, and the legs can be adjusted from 55 to 120 degrees. It is mechanically adjusted so does not require electricity, however, surgical staff need to be trained on how to perform needed adjustments during surgery. The open source surgical table has verified performance for mechanical loading over 130 kg, geometric flexibility to allow for wide array of common surgeries, is radiolucent in surgical zones, and is modular and upgradeable.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesOpen science
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.998
Threshold uncertainty score0.971

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0020.003
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.2900.123

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.211
Teacher spread0.191 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2022
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONESame topicAnatomy and Medical TechnologyFrench-language works237,207