MétaCan
Menu
Back to cohort
Record W4286716699 · doi:10.1038/s41598-022-16895-9

Evaluation of the contact surface between vertebral endplate and 3D printed patient-specific cage vs commercial cage

2022· article· en· W4286716699 on OpenAlexaff
Renan Fernandes, Aaron Gee, Andrew Kanawati, Fawaz Siddiqi, Parham Rasoulinejad, Radovan Zdero, Christopher S. Bailey

Bibliographic record

VenueScientific Reports · 2022
Typearticle
Languageen
FieldMedicine
TopicSpine and Intervertebral Disc Pathology
Canadian institutionsVictoria HospitalLondon Health Sciences CentreLawson Health Research InstituteWestern University
Fundersnot available
KeywordsCageCadaveric spasmMaterials scienceContact areaBiomedical engineeringImplantOrthodonticsAnatomyComposite materialMedicineSurgeryStructural engineering

Abstract

fetched live from OpenAlex

Abstract Biomechanical study. To evaluate the performance of the contact surface for 3D printed patient-specific cages using CT-scan 3D endplate reconstructions in comparison to the contact surface of commercial cages. Previous strategies to improve the surface of contact between the device and the endplate have been employed to attenuate the risk of cage subsidence. Patient-specific cages have been used to help, but only finite-element studies have evaluated the effectiveness of this approach. There is a possible mismatch between the CT-scan endplate image used to generate the cage and the real bony endplate anatomy that could limit the performance of the cages. A cadaveric model is used to investigate the possible mismatch between 3D printed patient-specific cages and the endplate and compare them to commercially available cages (Medtronic Fuse and Capstone). Contact area and contact stress were used as outcomes. When PS cage was compared to the Capstone cage, the mean contact area obtained was 100 ± 23.6 mm2 and 57.5 ± 13.7 mm2, respectively (p < 0.001). When compared to the Fuse cage, the mean contact area was 104.8 ± 39.6 mm2 and 55.2 ± 35.1 mm2, respectively(p < 0.001). Patient-specific cages improve the contact area between the implant and the endplate surface, reducing the contact stress and the risk of implant subsidence during LIF surgeries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.299
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueScientific ReportsSame topicSpine and Intervertebral Disc PathologyFrench-language works237,207