MétaCan
Menu
Back to cohort
Record W4288067667 · doi:10.1002/mp.15878

Catheters and dose optimization using a modified CVT algorithm and multi‐criteria optimization in prostate HDR brachytherapy

2022· article· en· W4288067667 on OpenAlexaff
Philippe Y. Chatigny, Cédric Bélanger, Éric Poulin, Luc Beaulieu

Bibliographic record

VenueMedical Physics · 2022
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsAlgorithmBrachytherapyComputer scienceRadiation treatment planningDosimetryProstate brachytherapyRadiation therapyMedicineNuclear medicineRadiology

Abstract

fetched live from OpenAlex

PURPOSE: Currently, in high-dose rate (HDR) brachytherapy planning, the catheter's positions are often selected by the planner, which involves the planner's experience. The catheters are then inserted using a template that helps to guide the catheters. For certain applications, it is of interest to choose the optimal location and number of catheters needed for dose coverage and potential decrease of the treatment's toxicity. Hence, it is of great importance to develop patient-specific algorithms for catheters and dose optimization. METHODS: A modified Centroidal Voronoi tessellation (CVT) algorithm is implemented and merged with a graphics processing unit (GPU)-based multi-criteria optimization algorithm (gMCO). The CVT algorithm optimizes the catheters' positions, and the gMCO algorithm optimizes the dwell times and dwell positions. The CVT algorithm can be used simultaneously for insertion with or without a template. Some improvements to the CVT algorithm are presented such as a new way of considering the area that needs to be covered. One hundred eight previously treated prostates HDR cases using real-time ultrasound are used to evaluate the different optimization procedures. The plan robustness is evaluated using two types of errors: deviations (random) in the insertion and deviation (systematic) in the reconstruction of the catheters. RESULTS: Using gMCO on clinically inserted catheter increases the acceptance rate by 37% for Radiation Therapy Oncology Group (RTOG) criteria. Our results show that all the patients respect RTOG criteria with 11 catheters using CVT+gMCO with a template of 5 mm. The number of catheters needed for all patients to respect RTOG criteria with the freehand technique is 10 catheters using CVT+gMCO. When deviations are introduced, using a template, the acceptance rate goes to 85% with 3 mm deviations using 11 catheters. This decrease is less significant when the number of catheters is higher, decreasing by less than 5% with a 3 mm deviation using 13 catheters or more. In conclusion, it is feasible to decrease the number of catheters needed to treat most patients. CONCLUSIONS: Some cases still need a high number of catheters to reach the plan's criteria. Using gMCO allows an increase in the plan quality, while using CVT reduces the number of catheters. A higher number of catheters equates to plans that are more robust to deviations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.009
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.307
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207