MétaCan
Menu
Back to cohort
Record W4289781874 · doi:10.1044/2022_jslhr-21-00209

Recognizing Voices Through a Cochlear Implant: A Systematic Review of Voice Perception, Talker Discrimination, and Talker Identification

2022· review· en· W4289781874 on OpenAlexaff
Sarah Colby, Adriel John Orena

Bibliographic record

VenueJournal of Speech Language and Hearing Research · 2022
Typereview
Languageen
FieldNeuroscience
TopicHearing Loss and Rehabilitation
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsCochlear implantSpeech perceptionAudiologyPerceptionPsychologyIdentification (biology)Noise (video)MedicineComputer science

Abstract

fetched live from OpenAlex

OBJECTIVE: Some cochlear implant (CI) users report having difficulty accessing indexical information in the speech signal, presumably due to limitations in the transmission of fine spectrotemporal cues. The purpose of this review article was to systematically review and evaluate the existing research on talker processing in CI users. Specifically, we reviewed the performance of CI users in three types of talker- and voice-related tasks. We also examined the different factors (such as participant, hearing, and device characteristics) that might influence performance in these specific tasks. DESIGN: We completed a systematic search of the literature with select key words using citation aggregation software to search Google Scholar. We included primary reports that tested (a) talker discrimination, (b) voice perception, and (c) talker identification. Each report must have had at least one group of participants with CIs. Each included study was also evaluated for quality of evidence. RESULTS: The searches resulted in 1,561 references, which were first screened for inclusion and then evaluated in full. Forty-three studies examining talker discrimination, voice perception, and talker identification were included in the final review. Most studies were focused on postlingually deafened and implanted adult CI users, with fewer studies focused on prelingual implant users. In general, CI users performed above chance in these tasks. When there was a difference between groups, CI users performed less accurately than their normal-hearing (NH) peers. A subset of CI users reached the same level of performance as NH participants exposed to noise-vocoded stimuli. Some studies found that CI users and NH participants relied on different cues for talker perception. Within groups of CI users, there is moderate evidence for a bimodal benefit for talker processing, and there are mixed findings about the effects of hearing experience. CONCLUSIONS: The current review highlights the challenges faced by CI users in tracking and recognizing voices and how they adapt to it. Although large variability exists, there is evidence that CI users can process indexical information from speech, though with less accuracy than their NH peers. Recent work has described some of the factors that might ease the challenges of talker processing in CI users. We conclude by suggesting some future avenues of research to optimize real-world speech outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.007
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.150
Threshold uncertainty score0.826

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.007
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.172
GPT teacher head0.455
Teacher spread0.283 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Speech Language and Hearing ResearchSame topicHearing Loss and RehabilitationFrench-language works237,207