MétaCan
Menu
Back to cohort
Record W4291020912 · doi:10.1111/anae.15823

Analgesic benefits of the quadratus lumborum block in total hip arthroplasty: a systematic review and meta‐analysis

2022· review· en· W4291020912 on OpenAlexaff
Nasir Hussain, Richard Brull, Jarod Speer, Leiming Hu, Tamara R. Sawyer, Colin J. L. McCartney, Faraj W. Abdallah

Bibliographic record

VenueAnaesthesia · 2022
Typereview
Languageen
FieldMedicine
TopicAnesthesia and Pain Management
Canadian institutionsSt. Michael's HospitalOttawa HospitalUniversity of OttawaWomen's College HospitalUniversity of Toronto
Fundersnot available
KeywordsMedicineAnalgesicAnesthesiaArthroplastyOpioidGeneral anaesthesiaPopulationRandomized controlled trialMeta-analysisContext (archaeology)MorphineHip surgerySurgeryInternal medicine

Abstract

fetched live from OpenAlex

The quadratus lumborum block (QLB) is reported to reduce pain and improve function following total hip arthroplasty; however, randomised controlled trials evaluating the benefits of adding this block to general or spinal anaesthesia in this population are conflicting. We performed a systematic review seeking randomised controlled trials investigating QLB benefits for total hip arthroplasty, stratifying comparisons regarding the addition of QLB to either general or spinal anaesthesia. The primary outcome was 24-h area under the curve (AUC) pain score. Pain scores were interpreted in the context of a population-specific minimal clinically important difference of 1.86 cm on a 10-cm visual analogue scale, or an AUC pain score of 5.58 cm.h. Secondary outcomes included analgesic consumption, functional recovery and opioid-related side-effects. In all, 18 trials (1318 patients) were included. Adding QLB to general or spinal anaesthesia improved 24-h AUC rest pain scores by a mean difference (95%CI) of -3.56 cm.h (-6.70 to -0.42; p = 0.034) and - 4.19 cm.h (-7.20 to -1.18; p = 0.014), respectively. These improvements failed to reach the pre-determined minimal clinically important difference, as did the reduction in analgesic consumption. Quadratus lumborum block improved functional recovery for general, but not spinal, anaesthesia. Opioid-related side-effects were reduced with QLB regardless of anaesthetic modality. Low-to-moderate quality evidence suggests that the extent to which adding QLB to either general or spinal anaesthesia reduces postoperative pain and opioid consumption after total hip arthroplasty is statistically significant but may be clinically unimportant for most patients. However, adding QLB to general anaesthesia might enhance functional recovery. Taken together, our findings do not support the routine use of QLB as part of multimodal analgesic regimens for total hip arthroplasty.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.013
Threshold uncertainty score0.029

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.014
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0130.020
Bibliometrics0.0040.005
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.292
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueAnaesthesiaSame topicAnesthesia and Pain ManagementFrench-language works237,207