Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Evidence-Based Analysis.

2015· article· en· W4292604931 on OpenAlexaboutno aff

Bibliographic record

VenuePubMed · 2015
Typearticle
Languageen
FieldMedicine
TopicColorectal Cancer Screening and Detection
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCapsule endoscopyColorectal cancerInternal medicineCochrane LibraryMeta-analysisGastroenterologyConfidence intervalColonoscopyColorectal PolypMEDLINEEndoscopyGrading (engineering)Cancer
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: Colorectal cancer, a leading cause of mortality and morbidity in Ontario, can be prevented through early diagnosis and removal of precancerous polyps. Colon capsule endoscopy is a relatively new, minimally invasive test for detecting colorectal polyps. OBJECTIVE: The objectives of this analysis were to evaluate the diagnostic accuracy and safety of colon capsule endoscopy for the detection of colorectal polyps among adult patients with signs or symptoms of colorectal cancer or with increased risk of colorectal cancer, and to compare colon capsule endoscopy with alternative procedures. REVIEW METHODS: A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid EMBASE, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2006 and 2014. Data on diagnostic accuracy and safety were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). RESULTS: The search yielded 2,189 citations. Five studies, all of which evaluated PillCam COLON 2 (PCC2), met the inclusion criteria. The per-patient sensitivity and specificity for detecting colorectal polyps were meta-analyzed. Colon capsule endoscopy, using PCC2, had a pooled sensitivity and specificity of 87% (95% confidence interval [CI] 77%-93%) and 76% (95% CI 60%-87%), respectively, for the detection of a colorectal polyp at least 6 mm in size (GRADE: very low). PCC2 had a pooled sensitivity and specificity of 89% (95% CI 77%-95%) and 91% (95% CI 86%-95%), respectively, for the detection of a colorectal polyp at least 10 mm in size (GRADE: low). One study directly compared PCC2 with computed tomographic (CT) colonography and found no statistically significant difference in accuracy (GRADE: low). Few adverse events were reported with PCC2; 3.9% of patients (95% CI 2.4%-6.5%) experienced adverse effects related to bowel preparation. Capsule retention was the most serious adverse event and occurred in 0.8% of patients (95% CI 0.2%-2.4%) (GRADE: very low). CONCLUSIONS: In adult patients with signs, symptoms, or increased risk of colorectal cancer, there is low-quality evidence that colon capsule endoscopy using the PCC2 device has good sensitivity and specificity for detecting colorectal polyps. Low-quality evidence does not show a difference in accuracy between colon capsule endoscopy and CT colonography. There is very low-quality evidence that PCC2 has a good safety profile with few adverse events; capsule retention is the most serious complication.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.783
Threshold uncertainty score0.293

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.084
GPT teacher head0.302
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2015
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicColorectal Cancer Screening and DetectionFrench-language works237,207