Demonstration and Performance Evaluation of Two Novel Algorithms for Removing Artifacts From Automated Intraoperative Temperature Data Sets: Multicenter, Observational, Retrospective Study

2022· article· en· W4292640777 on OpenAlexvenueno aff
Amit Bardia, Ranjit Deshpande, George Michel, David Yanez, Feng Dai, Nathan L. Pace, Kevin M. Schuster, Michael R. Mathis, Sachin Kheterpal, Robert B. Schonberger

Bibliographic record

VenueJMIR Perioperative Medicine · 2022
Typearticle
Languageen
FieldMedicine
TopicThermal Regulation in Medicine
Canadian institutionsnot available
FundersNational Center for Research ResourcesNational Heart, Lung, and Blood InstituteNational Institute on AgingUniversity of Texas MD Anderson Cancer CenterNational Center for Advancing Translational SciencesUniversity of Pennsylvania Health SystemVanderbilt UniversityUniversity of PennsylvaniaNational Institutes of HealthVanderbilt University Medical Center
KeywordsAlgorithmArtifact (error)Observational studyPerioperativeMedicineSensitivity (control systems)Retrospective cohort studyConfidence intervalComputer scienceSurgeryArtificial intelligenceInternal medicineEngineering

Abstract

fetched live from OpenAlex

BACKGROUND: The automated acquisition of intraoperative patient temperature data via temperature probes leads to the possibility of producing a number of artifacts related to probe positioning that may impact these probes' utility for observational research. OBJECTIVE: We sought to compare the performance of two de novo algorithms for filtering such artifacts. METHODS: In this observational retrospective study, the intraoperative temperature data of adults who received general anesthesia for noncardiac surgery were extracted from the Multicenter Perioperative Outcomes Group registry. Two algorithms were developed and then compared to the reference standard-anesthesiologists' manual artifact detection process. Algorithm 1 (a slope-based algorithm) was based on the linear curve fit of 3 adjacent temperature data points. Algorithm 2 (an interval-based algorithm) assessed for time gaps between contiguous temperature recordings. Sensitivity and specificity values for artifact detection were calculated for each algorithm, as were mean temperatures and areas under the curve for hypothermia (temperatures below 36 C) for each patient, after artifact removal via each methodology. RESULTS: A total of 27,683 temperature readings from 200 anesthetic records were analyzed. The overall agreement among the anesthesiologists was 92.1%. Both algorithms had high specificity but moderate sensitivity (specificity: 99.02% for algorithm 1 vs 99.54% for algorithm 2; sensitivity: 49.13% for algorithm 1 vs 37.72% for algorithm 2; F-score: 0.65 for algorithm 1 vs 0.55 for algorithm 2). The areas under the curve for time × hypothermic temperature and the mean temperatures recorded for each case after artifact removal were similar between the algorithms and the anesthesiologists. CONCLUSIONS: The tested algorithms provide an automated way to filter intraoperative temperature artifacts that closely approximates manual sorting by anesthesiologists. Our study provides evidence demonstrating the efficacy of highly generalizable artifact reduction algorithms that can be readily used by observational studies that rely on automated intraoperative data acquisition.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.576
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.170
GPT teacher head0.430
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Perioperative MedicineSame topicThermal Regulation in MedicineFrench-language works237,207