Efficacy and Safety of an Extravascular Implantable Cardioverter–Defibrillator
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS: A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS: In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it