MétaCan
Menu
Back to cohort
Record W4294238079 · doi:10.1002/acm2.13773

Novel multi jet fusion 3D‐printed patient immobilization for radiation therapy

2022· article· en· W4294238079 on OpenAlexaff
James L. Robar, Barret Kammerzell, Kevin Hulick, Pierre Kaiser, C. A. Young, Vanessa Verzwyvelt, Xin Cheng, M. R. Shepherd, Radojka Orbovic, Sara Fedullo, Christopher Majcher, Stephen DiMarco, J. Stasiak

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2022
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsGreenfield Research (Canada)Nova Scotia Health AuthorityDalhousie University
Fundersnot available
KeywordsMaterials scienceThermoplasticDosimetry3d printedBiomedical engineeringMetamaterial3D printingComposite materialNuclear medicineOptoelectronicsMedicine

Abstract

fetched live from OpenAlex

PURPOSE: Thermoplastic immobilizers are used routinely in radiation therapy to achieve positioning accuracy. These devices are variable in quality as they are dependent on the skill of the human fabricator. We examine the potential multi jet fusion (MJF) 3D printing for the production immobilizers with a focus on the surface dosimetry of several MJF-printed PA12-based material candidates. Materials are compared with the goal of minimizing surface dose with comparison to standard thermoplastic. We introduce a novel metamaterial design for the shell of the immobilizer, with the aims of mechanical robustness and low-dose buildup. We demonstrate first examples of adult and pediatric cranial and head-and-neck immobilizers. METHODS: Three different PA12 materials were examined and compared to fused deposition modeling-printed polylactic acid (PLA), PLA with density lowered by adding hollow glass microspheres, and to perforated or perforated/stretched and solid status quo thermoplastic samples. Build-up dose measurements were made using a parallel plate chamber. A metamaterial design was established based on a packed hexagonal geometry. Radiochromic film dosimetry was performed to determine the dependence of surface dose on the metamaterial design. Full cranial and head-and-neck prototype immobilizers were designed, printed, and assessed with regard to dimensional accuracy. RESULTS: Build-up dose measurements demonstrated the superiority of the PA12 material with a light fusing agent, which yielded a ∼15% dose reduction compared to other MJF materials. Metamaterial samples provided dose reductions ranging from 11% to 40% compared to stretched thermoplastic. MJF-printed immobilizers were produced reliably, demonstrated the versatility of digital design, and showed dimensional accuracy with 97% of sampled points within ±2 mm. CONCLUSIONS: MJF is a promising technology for an automated fabrication of patient immobilizers. Material selection and metamaterial design can be leveraged to yield surface dose reduction of up to 40%. Immobilizer design is highly customizable, and the first examples of MJF-printed immobilizers demonstrate excellent dimensional accuracy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.981
Threshold uncertainty score0.531

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.362
Teacher spread0.328 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207