MétaCan
Menu
Back to cohort

Development and Validation of HPLC-UV Method for the Determination of Favipiravir in Human Plasma

2022· article· en· W4294681241 on OpenAlexaff
Т. Н. Комаров, P. K. Karnakova, O. A. Archakova, D. S. Shchelgacheva, N. S. Bagaevа, I. E. Shohin, K. Ya. Zaslavskaya, P. A. Bely

Bibliographic record

VenueDrug development & registration · 2022
Typearticle
Languageen
FieldMedicine
TopicAntibiotics Pharmacokinetics and Efficacy
Canadian institutionsCanadian Public Health Association
Fundersnot available
KeywordsFavipiravirChromatographyHigh-performance liquid chromatographyChemistryPharmacokineticsProtein precipitationTherapeutic drug monitoringFormic acidPharmacologyMedicineCoronavirus disease 2019 (COVID-19)

Abstract

fetched live from OpenAlex

Introduction. Coronavirus disease (COVID-19) is an acute infectious disease caused by SARS-CoV-2 (severe acute respiratory syndrome-related coronavirus 2). Favipiravir is a synthetic prodrug with antiviral activity used for the treatment of COVID-19. There are oral and parenteral dosage forms of favipiravir. Compared with oral administration, parenteral administration has some advantages. Developing a method for the determination of favipiravir in human blood plasma is necessary for performing the analytical part of clinical studies of favipiravir for parenteral administration as an infusion, studying pharmacokinetics, and choosing the optimal dosage of the drug. Aim. The aim of this study is to develop and validate a method for quantitative determination of favipiravir in human plasma by high-performance liquid chromatography with ultraviolet detection (HPLC-UV) for pharmacokinetic studies. Materials and methods. Determination of favipiravir in human plasma by HPLC-UV. The UV detection was set at 323 ± 2 nm. The samples were processed by methanol protein precipitation. Internal standard: raltegravir. Mobile phase: 0.1 % formic acid in water with 0.08 % aqueous ammonia (eluent A), 0.1 % formic acid in acetonitrile with 0.08 % aqueous ammonia (eluent B). Column: Phenomenex Kinetex®, C18, 150 × 4.6 mm, 5 μm. Analytical range: 0.25–200.00 μg/mL. Results and discussion. This method was validated by selectivity, calibration curve, accuracy, precision, spike recovery, the lower limit of quantification, carry-over effect and stability. Conclusion. We developed and validated the method of quantitative determination of favipiravir in human plasma by HPLC-UV. The analytical range was 0.25–200.00 μg/mL in human plasma. The method could be applied in pharmacokinetics studies of favipiravir.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.004
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0030.001
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.338
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueDrug development & registrationSame topicAntibiotics Pharmacokinetics and EfficacyFrench-language works237,207