MétaCan
Menu
Back to cohort
Record W4294827394 · doi:10.1021/acs.langmuir.2c01242

Surface Nanodroplet-Based Extraction Combined with Offline Analytic Techniques for Chemical Detection and Quantification

2022· article· en· W4294827394 on OpenAlexafffund
Zhengxin Li, Hongyan Wu, Jae Bem You, Xiaomeng Wang, Hongbo Zeng, Detlef Lohse, Xuehua Zhang

Bibliographic record

VenueLangmuir · 2022
Typearticle
Languageen
FieldChemistry
TopicAnalytical chemistry methods development
Canadian institutionsNatural Resources CanadaUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of CanadaAlberta InnovatesH2020 European Research CouncilCanada First Research Excellence FundCanada Research ChairsUniversity of TwenteCanada Foundation for InnovationUniversity of Alberta
KeywordsExtraction (chemistry)ChemistryChromatographyNanotechnologyBiological systemMaterials scienceBiology

Abstract

fetched live from OpenAlex

Liquid–liquid extraction based on surface nanodroplets can be a green and sustainable technique to extract and concentrate analytes from a sample flow. However, because of the extremely small volume of each droplet (<10 fL, tens of micrometers in base radius and a few or less than 1 μm in height), only a few in situ analytical techniques, such as surface-enhanced Raman spectroscopy, were applicable for the online detection and analysis based on nanodroplet extraction. To demonstrate the versatility of surface nanodroplet-based extraction, in this work, the formation of octanol surface nanodroplets and extraction were performed inside a 3 m Teflon capillary tube. After extraction, surface nanodroplets were collected by injecting air into the tube, by which the contact line of surface droplets was collected by the capillary force. As the capillary allows for the formation of ∼1012 surface nanodroplets on the capillary wall, ≥2 mL of octanol can be collected after extraction. The volume of the collected octanol was enough for the analysis of offline analytical techniques such as UV–vis, GC-MS, and others. Coupled with UV–vis, reliable extraction and detection of two common water pollutants, triclosan and chlorpyrifos, was shown by a linear relationship between the analyte concentration in the sample solution and UV–vis absorbance. Moreover, the limit of detection (LOD) as low as 2 × 10–9 M for triclosan (∼0.58 μg/L) and 3 × 10–9 M for chlorpyrifos (∼1.05 μg/L) could be achieved. The collected surface droplets were also analyzed via gas chromatography (GC) and fluorescence microscopy. Our work shows that surface nanodroplet extraction may potentially streamline the process in sample pretreatment for sensitive chemical detection and quantification by using common analytic tools.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.178
Threshold uncertainty score0.518

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.297
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueLangmuirSame topicAnalytical chemistry methods developmentFrench-language works237,207