MétaCan
Menu
Back to cohort

A System-on-Board Integrated Multi-analyte PoC Biosensor for Combined Analysis of Saliva and Exhaled Breath

2022· article· en· W4294975660 on OpenAlexafffund
Roslyn S. Massey, Bruno Gamero, Ravi Prakash

Bibliographic record

Venue2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · 2022
Typearticle
Languageen
FieldEngineering
TopicAdvanced Chemical Sensor Technologies
Canadian institutionsCarleton University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsAnalyteBreath gas analysisSalivaBiosensorChromatographyExhaled airBiomedical engineeringMaterials scienceChemistryMedicineNanotechnologyInternal medicineBiology

Abstract

fetched live from OpenAlex

The need for oral health monitoring Point of Care (PoC) systems is ever growing. This is effectively highlighted by the ongoing COVID-19 pandemic where the lack of rapid PoC testing has placed an unsustainable burden on centralized laboratory testing. Urgent development has furthered pathogenic nucleic acid and antibody detection in oral samples throat swabs, but without corresponding advancements in biochemical monitoring through oral biosensing. We have recently reported two novel biosensor technologies for detection of high impact hormones: cortisol in saliva by organic electrolyte gated FETs (OEGFETs), and 8-isoprostane in exhaled breath condensate (EBC) using molecularly imprinted electroimpedance spectroscopy biosensors (MIP EIS). In this work, we report a first stage integration of the two biosensors - previously bench-top proven - with a miniaturized semi-hermetically sealed soft-fluidic enclosure, onto a low-power (<300 mW) customized printed circuit board. Our findings established comparable detection thresholds for the miniaturized board-based configuration and a lab-based test setup, and their ability to characterize, calibrate, and operate these small footprint biosensors. Testing with the 8-isoprostane EBC MIP EIS biosensors showed the system-on-board had an effective frequency range of 100-100kHz, comparable to lab bench impedance analyzers. Despite internal impedance increases of 210%, the expected data features are present in the impedance graphs collected with the PCB. The system-on-board experiments using OEGFET aptasensor showed a predictable behavior and comparable sensor detection range and resolution using unadulterated supernatant and serial dilutions of cortisol over a range of 273 μM to 2.73pM. The portable, multi-analyte oral biosensor is a promising prototype for future packaging and clinical validation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.286
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2022
Admission routes2
Has abstractyes

Explore more

Same venue2022 44th Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC)Same topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207