MétaCan
Menu
Back to cohort

Existing benchmark systems for assessing global warming potential of buildings – Analysis of IEA EBC Annex 72 cases

2022· article· en· W4295664424 on OpenAlexaff
Freja Nygaard Rasmussen, Damien Trigaux, E.A. Alsema, Maria Balouktsi, Harpa Birgisdóttir, Rolf André Bohne, Manish Dixit, David Dowdell, Nicolas Francart, Rolf Frischknecht, Greg Foliente, Antonín Lupíšek, Thomas Lützkendorf, Tove Malmqvist, Antonio García Martínez, Claudiane Ouellet‐Plamondon, Alexander Passer, Bruno Peuportier, L Ramseier, Daniel Satoła, S Seo, Zsuzsa Szalay, Marianne Kjendseth Wiik

Bibliographic record

VenueIOP Conference Series Earth and Environmental Science · 2022
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsBenchmark (surveying)Environmental scienceGlobal warmingMeteorologyClimatologyComputer scienceClimate changeGeographyCartographyGeology

Abstract

fetched live from OpenAlex

Abstract Life cycle assessment (LCA) is increasingly being used as a tool by the building industry and actors to assess the global warming potential (GWP) of building activities. In several countries, life cycle based requirements on GWP are currently being incorporated into building regulations. After the establishment of general calculation rules for building LCA, a crucial next step is to evaluate the performance of the specific building design. For this, reference values or benchmarks are needed, but there are several approaches to defining these. This study presents an overview of existing benchmark systems documented in seventeen cases from the IEA EBC Annex 72 project on LCA of buildings. The study characterizes their different types of methodological background and displays the reported values. Full life cycle target values for residential and non-residential buildings are found around 10-20 kg CO 2 e/m 2 /y, whereas reference values are found between 20-80 kg CO2e/m 2 /y. Possible embodied target- and reference values are found between 1-12 kg CO 2 e/m 2 /y for both residential and non-residential buildings. Benchmark stakeholders can use the insights from this study to understand the justifications of the background methodological choices and to gain an overview of the level of GWP performance across benchmark systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.052
Threshold uncertainty score0.442

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.217
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueIOP Conference Series Earth and Environmental ScienceSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207