MétaCan
Menu
Back to cohort
Record W4296130293 · doi:10.1101/2022.09.11.507374

An impedance-based chemiresistor for the real-time detection of gut microbiota-generated short-chain fatty acids

2022· preprint· en· W4296130293 on OpenAlexafffund
Adel Yavarinasab, Stéphane Flibotte, Sijie Liu, Carolina Tropini

Bibliographic record

VenuebioRxiv (Cold Spring Harbor Laboratory) · 2022
Typepreprint
Languageen
FieldEngineering
TopicAdvanced Chemical Sensor Technologies
Canadian institutionsCanadian Institute for Advanced ResearchUniversity of British Columbia
FundersCanadian Institutes of Health ResearchCrohn's and Colitis CanadaMichael Smith Health Research BCCanadian Institute for Advanced Research
KeywordsButyric acidDielectric spectroscopyEvaporationMaterials scienceExtraction (chemistry)ElectrodeChromatographyChemistryAnalytical Chemistry (journal)ElectrochemistryBiochemistry

Abstract

fetched live from OpenAlex

Abstract Short-chain fatty acids (SCFAs) are key molecules produced by gut bacteria in the intestine, that are absorbed into the bloodstream and strongly influence human health. SCFA disruption and imbalances have been linked to many diseases; however, they are seldom used diagnostically as their detection requires extensive sample preparation and expensive equipment. In this work, an electrochemical sensor was developed to enable real-time, quantitative measurement of SCFAs from complex samples in liquid phase without the need for extraction, evaporation, or destruction. An impedance-based sensor for in vitro detection of acetic acid, propionic acid, and butyric acid (accounting for more than 95% of SCFAs in the intestine) was fabricated by the deposition of a ZnO and polyvinyl alcohol (PVA) on the surface of a microfabricated interdigitated gold electrode. The sensor was first exposed to a broad, physiologically relevant range of concentrations of SCFAs in isolation (0.5–20 mg/ml) and unlike previously published SCFA sensors that could detect only in gas form with the aid of evaporation, it was able to detect them directly in the liquid phase at room temperature. Electrochemical impedance spectroscopy analysis was then applied to the mixture of SCFAs prepared at different ratios and in complex media at concentrations ranging from 0.5 to 10 mg/ml, which showed the capability of the sensor to measure SCFAs in experimentally relevant mixture. The recorded faradaic responses were then used to train a fit-to-data model to utilize the sensor to screen human bacterial isolates and detect which species secrete SCFAs in vitro . This work will allow for the rapid and non-destructive determination of the levels of SCFAs in complex biological samples, providing a miniaturized, highly stable, and highly sensitive sensor for real-time monitoring applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.214
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuebioRxiv (Cold Spring Harbor Laboratory)Same topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207