MétaCan
Menu
Back to cohort
Record W4296450886 · doi:10.3390/su14159780

Modeling and Performance Analysis for High-Rise Building Using ArchiCAD: Initiatives towards Energy-Efficient Building

2022· article· en· W4296450886 on OpenAlexaff
Siti Birkha Mohd Ali, Amirhossein Mehdipoor, Noora Samsina Johari, M. Hasanuzzaman, Nasrudin Abd Rahim

Bibliographic record

VenueSustainability · 2022
Typearticle
Languageen
FieldEngineering
TopicBIM and Construction Integration
Canadian institutionsÉcole de Technologie Supérieure
FundersMinistry of Higher Education, Malaysia
KeywordsRetrofittingGlazingEnergy consumptionEfficient energy useArchitectural engineeringEnergy conservationCooling loadAuditBuilding information modelingComputer scienceEnvironmental economicsCivil engineeringEngineeringOperations managementMechanical engineeringAir conditioningBusinessStructural engineeringScheduling (production processes)

Abstract

fetched live from OpenAlex

An energy-efficient building is not built in a day. It requires effective processes, approaches, and tools, as well as high commitment from all the involved parties. A similar requirement is needed for effective retrofitting practice. Building Information Modelling (BIM) is one of the sensible processes in ensuring either the new building development or retrofitting initiatives arrive at its ultimate objectives, i.e., reduction in energy consumption, energy cost, and removal of harmful emissions. Many studies had proved that a window is one of the building elements that could contribute to establishing an energy-efficient building. Therefore, a 25-floor Wisma R&D, University of Malaya building was modeled using ArchiCAD to analyse the influences of window glazing, opaque materials, and shading elements on overall building energy performances. The accuracy of the model and simulation outcome was initially compared with the energy audit result conducted from March to May 2017. Consequently, this study revealed that the effective combinations of the window parameters had assisted in improving the infiltration rate and heat transfer coefficient which allowed a lower cooling load within 3% to 6%, respectively. After most, minimum savings of 18,133.9 kWh, RM 6618.88, and 1265.16 kg of carbon dioxide (CO2) were gained through a reduction of cooling load in Wisma R&D based on the window system improvement. This article aims to promote the capability of ArchiCAD as a practical tool for effective retrofitting decision-making. Ultimately, this study revealed the importance of a multivariate framework in building energy conservation and provide an insight into the improvement of the Malaysia Standard MS1525:2019, mainly for high-rise buildings in Malaysia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.434
Threshold uncertainty score0.613

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.249
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueSustainabilitySame topicBIM and Construction IntegrationFrench-language works237,207