MétaCan
Menu
Back to cohort
Record W4297100681 · doi:10.1088/1361-6560/ac9510

Quantification of pulmonary functional MRI: state-of-the-art and emerging image processing methods and measurements

2022· review· en· W4297100681 on OpenAlexafffund
Maksym Sharma, Paulina V. Wyszkiewicz, Vedanth Desaigoudar, Fumin Guo, Dante P. I. Capaldi, Grace Párraga

Bibliographic record

VenuePhysics in Medicine and Biology · 2022
Typereview
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsUniversity of TorontoRobarts Clinical TrialsSunnybrook Health Science CentreWestern University
FundersCanadian Institutes of Health Research
KeywordsComputer scienceImage processingFocus (optics)Ventilation (architecture)Medical imagingMedical physicsBiomedical engineeringArtificial intelligenceMedicineImage (mathematics)PhysicsOptics

Abstract

fetched live from OpenAlex

Abstract Pulmonary functional magnetic resonance imaging (PfMRI) provides a way to non-invasively map and measure the spatial distribution of pulmonary ventilation, perfusion and gas-exchange abnormalities with unprecedented detail of functional processes at the level of airways, alveoli and the alveolar-capillary membrane. Current PfMRI approaches are dominated by hyperpolarized helium-3 ( 3 He) and xenon-129 ( 129 Xe) gases, which both provide rapid (8–15 s) and well-tolerated imaging examinations in patients with severe pulmonary diseases and pediatric populations, whilst employing no ionizing radiation. While a number of review papers summarize the required image acquisition hardware and software requirements needed to enable PfMRI, here we focus on the image analysis and processing methods required for reproducible measurements using hyperpolarized gas ventilation MRI. We start with the transition in the literature from qualitative and subjective scoring systems to quantitative and objective measurements which enable precise quantification of the lung’s critical structure-function relationship. We provide an overview of quantitative biomarkers and the relevant respiratory system parameters that may be measured using PfMRI methods, outlining the history of developments in the field, current methods and then knowledge gaps and typical limitations. We focus on hyperpolarized noble gas MR image processing methods used for quantifying ventilation and gas distribution in the lungs, and discuss the utility and applications of imaging biomarkers generated through these techniques. We conclude with a summary of the current and future directions to further the development of image processing methods, and discuss the remaining challenges for potential clinical translation of these approaches and their integration into standard clinical workflows.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.993
Threshold uncertainty score0.510

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.434
GPT teacher head0.506
Teacher spread0.072 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAtomic and Subatomic Physics ResearchFrench-language works237,207