MétaCan
Menu
Back to cohort
Record W4297229296 · doi:10.24297/ijct.v22i.9288

In-silico patient-specific and patient-appropriate engineering method to judiciously select an ameliorative implant design in a single-patient using finite element-n-of-1 (fe-n-of-1) empirical test analysis to reconstruct mid-sagittal osteochondrotomy of the sternum following cardiac surgery

2022· article· en· W4297229296 on OpenAlexaff
Harjeet Singh Gandhi

Bibliographic record

VenueINTERNATIONAL JOURNAL OF COMPUTERS & TECHNOLOGY · 2022
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsHamilton Health Sciences
Fundersnot available
KeywordsFinite element methodImplantTest (biology)SternumComputer scienceTest caseProtocol (science)Empirical researchStructural engineeringEngineeringMedicineSurgeryMathematicsMachine learningStatistics

Abstract

fetched live from OpenAlex

Introduction: No two patients have similar normal anatomy and physiology because of genetics, physical development, and age that the same type of surgery and reconstruction implant will perform equally well. Such a notion demands the need for individualization of treatment and a method to select an ameliorative implant prospectively. One such empirically testing method is the finite element-n-of-1 (fe-n-of-1), where a treatment plan is executed specifically and systematically for a single patient as part of pre-operative planning. Objective: It is to evaluate and discuss the method of finite element analysis to carry out the fe-n-of-1 empirical test in a fact-driven manner connecting various scientific domains. It presents a preliminary protocol how to select an ameliorative implant to mitigate sternal instability due to suboptimal standard stainless-steel cerclage wiring to reconstruct the sternum following open-heart surgery. Methodology: The instability following the reconstruction of the sternum is a mechanical problem therefore it is appropriate to apply harmless structural engineering methods to choose a suitable implant design to fix it. This exploratory descriptive research describes finite element n-of-1 empirical testing using in-silico engineering principles applied to patient-specific and patient-appropriate mechanical loading conditions. Conclusion: Single-patient fe-n-of-1 empirical testing is a benign engineering method based on finite element modeling and finite element analysis. It is a safe mathematical evaluation free from subjective bias to select in advance the most ameliorative implant design to opt out of the suboptimal stainless steel cerclage wire as ‘standard of care’ and improve patient-based outcome and surgeon satisfaction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.559
Threshold uncertainty score0.610

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0030.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.287
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueINTERNATIONAL JOURNAL OF COMPUTERS & TECHNOLOGYSame topicOrthopaedic implants and arthroplastyFrench-language works237,207