MétaCan
Menu
Back to cohort
Record W4297237151 · doi:10.3390/s22197274

Optical Monitoring of Breathing Patterns and Tissue Oxygenation: A Potential Application in COVID-19 Screening and Monitoring

2022· article· en· W4297237151 on OpenAlexaff
Aaron James Mah, Thien Nguyen, Leili Ghazi Zadeh, Atrina Shadgan, Kosar Khaksari, Mehdi Nourizadeh, Ali Zaidi, Soongho Park, Amir Gandjbakhche, Babak Shadgan

Bibliographic record

VenueSensors · 2022
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsInternational Collaboration On Repair DiscoveriesUniversity of British Columbia
Fundersnot available
KeywordsBreathingRespiratory monitoringMedicineRespiratory systemRespiratory rateVentilation (architecture)ExhalationContinuous monitoringBiomedical engineeringCardiologyAudiologyAnesthesiaInternal medicineHeart rate

Abstract

fetched live from OpenAlex

The worldwide outbreak of the novel Coronavirus (COVID-19) has highlighted the need for a screening and monitoring system for infectious respiratory diseases in the acute and chronic phase. The purpose of this study was to examine the feasibility of using a wearable near-infrared spectroscopy (NIRS) sensor to collect respiratory signals and distinguish between normal and simulated pathological breathing. Twenty-one healthy adults participated in an experiment that examined five separate breathing conditions. Respiratory signals were collected with a continuous-wave NIRS sensor (PortaLite, Artinis Medical Systems) affixed over the sternal manubrium. Following a three-minute baseline, participants began five minutes of imposed difficult breathing using a respiratory trainer. After a five minute recovery period, participants began five minutes of imposed rapid and shallow breathing. The study concluded with five additional minutes of regular breathing. NIRS signals were analyzed using a machine learning model to distinguish between normal and simulated pathological breathing. Three features: breathing interval, breathing depth, and O2Hb signal amplitude were extracted from the NIRS data and, when used together, resulted in a weighted average accuracy of 0.87. This study demonstrated that a wearable NIRS sensor can monitor respiratory patterns continuously and non-invasively and we identified three respiratory features that can distinguish between normal and simulated pathological breathing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.254
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueSensorsSame topicNon-Invasive Vital Sign MonitoringFrench-language works237,207