Reliability of the Pediatric Specific Musculoskeletal Ultrasound Scoring Systems for the Elbow, Wrist, and Finger Joints
Bibliographic record
Abstract
OBJECTIVE: Musculoskeletal ultrasound (MSUS) is increasingly being used in the evaluation of pediatric musculoskeletal diseases. In order to provide objective assessments of arthritis, reliable MSUS scoring systems are needed. Recently, joint-specific scoring systems for arthritis of the pediatric elbow, wrist, and finger joints were proposed by the Childhood Arthritis and Rheumatology Research Alliance (CARRA) MSUS workgroup. This study aimed to assess the reliability of these scoring systems when used by sonographers with different levels of expertise. METHODS: Members of the CARRA MSUS workgroup attended training sessions for scoring the elbow, wrist, and finger. Subsequently, scoring exercises of B mode and power Doppler (PD) mode still images for each joint were performed. Interreader reliability was determined using 2-way single-score intraclass correlation coefficients (ICCs) for synovitis and Cohen [Formula: see text] for tenosynovitis. RESULTS: Seventeen pediatric rheumatologists with different levels of MSUS expertise (1-15 yrs) completed a 2-hour training session and calibration exercise for each joint. Excellent reliability (ICC > 0.75) was found after the first scoring exercise for all the finger and elbow views evaluated on B mode and PD mode, and for all of the wrist views on B mode. After a second training session and a scoring exercise, the wrist PD mode views reached excellent reliability as well. CONCLUSION: The preliminary CARRA MSUS scoring systems for assessing arthritis of the pediatric elbow, wrist, and finger joints demonstrate excellent reliability among pediatric MSUS sonographers with different levels of expertise. With further validation, this reliable joint-specific scoring system could serve as a clinical tool and scientific outcome measure.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.003 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".