MétaCan
Menu
Back to cohort
Record W4301322394 · doi:10.3791/58430-v

Normothermic Ex Situ Heart Perfusion in Working Mode: Assessment of Cardiac Function and Metabolism

2019· article· en· W4301322394 on OpenAlexaff
Sanaz Hatami, Christopher W. White, Martin Ondrus, Qi Xiao, Max Buchko, Sayed Himmat, Lily Lin, Katie Cameron, David S. Nobes, Hyun‐Joong Chung, Jayan Nagendran, Darren H. Freed

Bibliographic record

VenueJournal of Visualized Experiments · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsPerfusionIn situCardiologyCardiac function curveMedicineInternal medicineMetabolismChemistryHeart failure

Abstract

fetched live from OpenAlex

The current standard method for organ preservation (cold storage, CS), exposes the heart to a period of cold ischemia that limits the safe preservation time and increases the risk of adverse post-transplantation outcomes. Moreover, the static nature of CS does not allow for organ evaluation or intervention during the preservation interval. Normothermic ex situ heart perfusion (ESHP) is a novel method for preservation of the donated heart that minimizes cold ischemia by providing oxygenated, nutrient-rich perfusate to the heart. ESHP has been shown to be non-inferior to CS in the preservation of standard-criteria donor hearts and has also facilitated the clinical transplantation of the hearts donated after the circulatory determination of death. Currently, the only available clinical ESHP device perfuses the heart in an unloaded, non-working state, limiting assessments of myocardial performance. Conversely, ESHP in working mode provides the opportunity for comprehensive evaluation of cardiac performance by assessment of functional and metabolic parameters under physiologic conditions. Moreover, earlier experimental studies have suggested that ESHP in working mode may result in improved functional preservation. Here, we describe the protocol for ex situ perfusion of the heart in a large mammal (porcine) model, which is reproducible for different animal models and heart sizes. The software program in this ESHP apparatus allows for real-time and automated control of the pump speed to maintain desired aortic and left atrial pressure and evaluates a variety of functional and electrophysiological parameters with minimal need for supervision/manipulation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.646
Threshold uncertainty score0.420

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.410
Teacher spread0.390 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Visualized ExperimentsSame topicCardiac Imaging and DiagnosticsFrench-language works237,207